fMRI retinotopic mapping at 3 T: benefits gained from correcting the spatial distortions due to static field inhomogeneity.

نویسندگان

  • Flor Vasseur
  • Chantal Delon-Martin
  • Cécile Bordier
  • Jan Warnking
  • Laurent Lamalle
  • Christoph Segebarth
  • Michel Dojat
چکیده

fMRI retinotopic mapping usually relies upon Fourier analysis of functional responses to periodic visual stimuli that encode eccentricity or polar angle in the visual field. Generally, phase estimations are assigned to a surface model of the cerebral cortex and borders between retinotopic areas are eventually determined following ad hoc phase analysis on the surface model. Assigning functional responses to a surface model of the cortex is particularly sensitive to geometric distortions of the 3D functional data due to static field inhomogeneity. Here, we assess and document the benefits gained from correcting the fMRI data for these effects, under standard experimental conditions (echo-planar imaging, 3.0-T field strength) and with well-chosen acquisition parameters (regarding slice orientation and phase-encoding direction). While it appears that, in the absence of correction, errors in the estimates of the borders between low-order visual areas do not then significantly exceed the variance of statistical origin, about half of the functional responses in a retinotopic experiment are misassigned to neighboring functional areas. Therefore, correction of the effects due to geometric distortions is important in any retinotopic mapping experiment and by extension in any fMRI experiment on the visual system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Motion Correction in fMRI by Mapping Slice-to-Volume with Concurrent Field-Inhomogeneity Correction

Head motion is the major source of error in measuring intensity changes related to given stimuli in fMRI. The effects of head motion are image shifts and field inhomogeneity variations which cause local changes in geometric distortions. The previously developed motion correction method, mapping slice-to-volume (MSV), retrospectively remaps slices that are shifted by head motion to their spatial...

متن کامل

Geometric distortion correction in echo volumar imaging

Introduction: Echo volumar imaging (EVI) is a 3D extension of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single excitation. However, only a few studies to date have applied EVI to functional MRI (fMRI) due to its high sensitivity to field-inhomogeneity induced distortions. In this study, we extend two EPI distortion correction techniques to EVI: ...

متن کامل

Image distortion correction in fMRI: A quantitative evaluation.

A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A...

متن کامل

Multishot versus Single-Shot Pulse Sequences in Very High Field fMRI: A Comparison Using Retinotopic Mapping

High-resolution functional MRI is a leading application for very high field (7 Tesla) human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR) and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vision

دوره 10 12  شماره 

صفحات  -

تاریخ انتشار 2010