Transcatheter occlusion of a Blalock-Taussig shunt with a detachable balloon in a child.
نویسندگان
چکیده
A case of transcatheter occlusion of a Blalock-Taussig shunt with a detachable silicone filled balloon is described. This 11 year old boy had previously had a repair of tetralogy of Fallot together with ligation of a large Blalock-Taussig shunt. Though there was a good surgical result, the shunt proved to be incompletely closed leaving a significant left to right shunt. As an alternative to a further operation a silicone filled balloon was detached in the Blalock-Taussig shunt and this successfully closed the fistula.
منابع مشابه
Recanalisation of an occluded modified Blalock-Taussig shunt by balloon dilatation.
A four year old boy with pulmonary atresia and ventricular septal defect had an acute cyanotic episode three years after undergoing a right-sided, 6 mm diameter, modified Blalock-Taussig shunt. On admission no continuous murmur could be heard from the shunt and the typical high velocity, continuous flow profile of the shunt could not be identified by Doppler echocardiography. At catheterisation...
متن کاملBalloon occlusion of the carotid artery for the angiographic visualization of Blalock-Taussig shunts and pulmonary arteries.
We describe the use of a balloon catheter to occlude the right or left carotid artery as a way of directing contrast material to the pulmonary arteries. This procedure was carried out in the postoperative study of 14 children who had undergone a Blalock-Taussig shunt. The method was reliable, and the angiograms provided excellent visualization of the pulmonary arteries using only small volumes ...
متن کاملModified Blalock-taussig Shunt ----in- Hospital Shunt Occlusion: Experience at Nicvd
A modified Blalock-Taussig shunt (mBTS) is a surgically placed graft between the systemic and pulmonary arterial circulations that redirects systemic blood flow into the pulmonary circulation. It is often placed in those with rightsided obstructive cardiac defects to increase pulmonary blood flow. Postoperative shunt patency is critical to adequate systemic oxygenation. Nevertheless, in the imm...
متن کاملPulmonary atresia with intact ventricular septum percutaneous radiofrequency-assisted valvotomy and balloon dilation versus surgical valvotomy and Blalock Taussig shunt.
OBJECTIVE We compared the result of radiofrequency (RF)-assisted valvotomy and balloon dilation with closed surgical valvotomy and Blalock Taussig (BT) shunt as primary treatment in selected patients with pulmonary atresia and intact ventricular septum (PA-IVS). BACKGROUND Patients with PA-IVS who have mild to moderate hypoplasia of the right ventricle (RV) and patent infundibulum have the gr...
متن کاملClosure of Blalock-Taussig shunts using a new detachable coil device.
Two children underwent interventional closure of a modified Blalock-Taussig shunt using a new detachable coil system (Duct-Occlud). This procedure has advantages over currently available materials to occlude these and other communications between the systemic and pulmonary circulations.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 50 1 شماره
صفحات -
تاریخ انتشار 1983