Concurrent validity and intertester reliability of universal and fluid-based goniometers for active elbow range of motion.
نویسندگان
چکیده
The purposes of this study were 1) to establish the concurrent validity of the universal goniometer and the fluid-based goniometer and 2) to determine the intertester reliability of these two instruments. A correlational study was performed in which two testers used the universal goniometer and the fluid-based goniometer in measuring elbow range of motion in 30 healthy subjects. The fluid-based goniometer had high intertester reliability (R = .92), and the standard goniometer had poor reliability (R = .53). The Pearson product-moment correlation between the two instruments was .83. A significant difference was shown between the standard goniometer and the fluid-based goniometer by the t test (t = 4.4, df = 28, p less than .05). The results support the use of the fluid-based goniometer between testers on elbow range of motion; however, the two instruments cannot be used interchangeably.
منابع مشابه
Intertester reliability and concurrent validity of fluid-based and universal goniometers for active knee flexion.
This study was designed 1) to determine the intertester reliability of the universal goniometer and the fluid-based goniometer and 2) to establish the concurrent validity of the fluid-based goniometer. Two testers measured active knee flexion of 20 healthy subjects (15 women, 5 men) using both instruments. The subjects had a mean age of 24.8 years (s = 5.5) and reported no previous history of p...
متن کاملPsychometric properties of measurement tools for quantifying knee joint position and movement: a systematic review.
This systematic review critically evaluates literature on the reliability and validity of measurement tools for quantifying knee joint angles and knee movement. A search was conducted of seven medical databases and one biomedical engineering database, yielding 43 articles that reported reliability or validity. Tools for quantifying knee joint angles included standard handheld goniometers, fluid...
متن کاملValidity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.
BACKGROUND The aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls. METHODS Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simu...
متن کاملThe Reliability and Concurrent Validity of Digital Inclinometer, Smartphone Applications, and the Cervical Range of Motion Device for Measuring the Cervical Range of Motion
Objectives: Changes in the Range of Motion (ROM) are essential criteria in determining the severity of spinal disorders and could be effective in predicting pain progression. Instruments to measure the ROM are costly and unavailable in most therapy settings. While there is a tendency in therapists to use their smartphones instead, there is no report to measure the suitability of smartphones to ...
متن کاملReliability and Validity of Electro-Goniometric Range of Motion Measurements in Patients with Hand and Wrist Limitations
STUDY DESIGN Cross-sectional reliability and validity study. PURPOSE 1. To determine intrarater, interrater and inter instrument reliabilities and validity of two digital electro goniometry to measure active wrist/finger range of motions (ROMs) in patients with limited motion. 2. To determine intrarater and interrater reliabilities of digital goniometry to measure torques of PIP passive flexi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical therapy
دوره 68 6 شماره
صفحات -
تاریخ انتشار 1988