Diagnosis of inhomogeneous insulation degradation in electric cables by distributed shunt conductance estimation ¬リニ

نویسندگان

  • Qinghua Zhang
  • Huaibin Tang
چکیده

For the diagnosis of inhomogeneous insulation degradation in electric cables, the estimation of distributed shunt conductance is studied in this paper. Gradual growth of the shunt conductance is a consequence of degradation of the dielectric properties of the insulator. The proposed estimation method is based on voltage and current measurements at a single end of the cable. After the linearization of the bilinear term of the telegrapher's equations through a perturbation approach, the Kalman filter is applied to transform the problem of dynamic system parameter estimation to a simple linear regression problem. Results of numerical simulations are presented to demonstrate the feasibility of the proposed method. In particular, it is shown that the weak sensitivity of the available measurements to the shunt conductance can be compensated by long time data samples. & 2013 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cable Selection and Shunt Compensation for Offshore Windparks

The transmission of the electric power to shore and concepts for the electrical system of offshore wind farms are evaluated with respect to selection of a cable. Necessity of use of a shunt by an AC cable connection to shore is addressed, Consequences of the use of a higher insulation of cables, use of three single core cables in triangular and linear configuration is compared in the paper.

متن کامل

مکان یابی برقگیر در مزرعه بادی به کمک الگوریتم ژنتیک

Due to the ever-increasing use of Distributed Generations (DGs), and special attentions toward wind power plants in recent years, this research investigates the wind plants from the viewpoint of lightning protection. In comparison to all other type of generators connected to the electric power systems, wind turbine generators are placed in areas which are more likely to be stricken by lightning...

متن کامل

Experience with dielectric response measurements on oil-paper insulated cables

Deterioration of the underground power cables insulation has been established to be caused by electrical, thermal and environmental stresses. With the degradation of dielectric strength of the insulation, the underground cables will not be able to function optimally or as planned. As a supplement to the existing dissipation factor and other conventional cable diagnostic measurements, the Decay ...

متن کامل

DC Model Cable under Polarity Inversion and Thermal Gradient: Build-Up of Design-Related Space Charge

In the field of energy transport, High-Voltage DC (HVDC) technologies are booming at present due to the more flexible power converter solutions along with needs to bring electrical energy from distributed production areas to consumption sites and to strengthen large-scale energy networks. These developments go with challenges in qualifying insulating materials embedded in those systems and in t...

متن کامل

New EEM/BEM Hybrid Method for Electric Field Calculation in Cable Joints

A power cable is widely used for power supply in power distributing networks and power transmission lines. Due to limitations in the production, delivery and setting up power cables, they are produced and delivered in several separate lengths. Cable itself, consists of two cable terminations and arbitrary number of cable joints, depending on the cable route length. Electrical stress control is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016