Working Length Determination Using Cone-Beam Computed Tomography, Periapical Radiography and Electronic Apex Locator in Teeth with Apical Periodontitis: A Clinical Study
نویسندگان
چکیده
INTRODUCTION The purpose of this clinical study was to compare the accuracy of working length (WL) determination using cone-beam computed tomography (CBCT), conventional periapical radiographies and electronic apex locator. METHODS AND MATERIALS This study was conducted during root canal treatment of 19 patients with a total of 30 single-rooted teeth diagnosed with apical periodontitis. After taking the initial parallel periapical radiographies, the initial file was advanced into the canal until the WL was detected by the apex locator. Subsequently, the WL was measured and WL radiographies were taken with the file set in the canal. Afterwards, CBCT images were acquired. These three measurements were tabulated and compared and the data were analyzed using the Friedman test. The level of significance was set at 0.05. RESULTS The mean values for WL determination by electronic apex locator, periapical radiograph and CBCT images were 22.25, 22.43 and 22.65, respectively which was not statistically significant (P>0.05). CONCLUSION Working length determination using CBCT images was precise when compared to radiographic method and electronic apex locator.
منابع مشابه
Evaluation of Conventional Radiography and an Electronic Apex Locator in Determining the Working Length in C-shaped Canals
INTRODUCTION The purpose of this in vitro study was to compare the accuracy of working length determination using the apex locator versus conventional radiography in C-shaped canals. METHODS AND MATERIALS After confirming the actual C-shaped anatomy using cone-beam computed tomography (CBCT), 22 extracted C-shaped mandibular second molars were selected and decoronated at the cemento-enamel ju...
متن کاملInvestigating Root Canal Number and Morphology of Mandibular Anterior Teeth Using Cone Beam Computed Tomography
Background and purpose: Root therapy will be successful if it is done based on a correct diagnosis and appropriate treatment plan with the knowledge of morphology and tooth anatomy, debridement, disinfection, and obturation of the entire root canal system. This study aimed to investigate the number and morphology of canals in root canals mandibular anterior using cone beam computed tomography (...
متن کاملIn vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
متن کاملارزیابی دقت یک نوع Electronic Apex Locator در تعیین طول دندانهای شیری (In-vitro)
Statement of Problem: Radiography is the most common technique in working length determination, however, because of its limitations is not considered as an ideal technique. Its application, particularly for children due to radiation hazards, technical problems in young and unco-operative children and the superimposition of permanent teeth bud on primary teeth root, lead to numerous problems.Pur...
متن کاملInfluence of intracanal post on apical periodontitis identified by cone-beam computed tomography.
The determination of the success of endodontic treatment has been often discussed based on outcome obtained by periapical radiography. The aim of this study was to verify the influence of intracanal post on apical periodontitis detected by cone-beam computed tomography (CBCT). A consecutive sample of 1020 images (periapical radiographs and CBCT scans) taken from 619 patients (245 men; mean age,...
متن کامل