Reverse Optic Capture to Stabilize a Toric Intraocular Lens
نویسندگان
چکیده
PURPOSE To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL). METHOD Case report and literature review. RESULTS Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC) are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications. CONCLUSIONS ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively.
منابع مشابه
Scleral fixation of a one-piece toric intraocular lens.
PURPOSE To describe a novel technique for toric intraocular lens (IOL) repositioning and fixation in the absence of adequate capsular support. METHODS Case report and literature review. RESULTS Two cases are presented with scleral fixation of a one-piece toric IOL (SN6AT series; Alcon Laboratories, Inc., Fort Worth, TX). In both cases, toric IOLs initially placed within the capsular bag bec...
متن کاملIntraocular Lens Optic Capture in Pediatric Cataract Surgery
Posterior capsulorhexis with optic capture was originally described by Gimbel and DeBroff [4] to maintain a clear visual axis after pediatric cataract surgery. This technique involves capturing the IOL optic through a primary posterior continuous curvilinear capsulorhexis (PCCC), while the haptics remain within the capsular bag (Figure 1). Studies have demonstrated this to be a valuable techniq...
متن کاملSuccessful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
INTRODUCTION We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. CASE PRESENTATION A 53-year-old woman had undergone toric implan...
متن کاملJOURNAL OF MEDICAL CASE REPORTS Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
Introduction: We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation: A 53-year-old woman had undergone toric implan...
متن کاملRefractive lens exchange using SN60T5 AcrySof Toric intraocular lens in stage 2 keratoconus
This is a case report of a 45-year-old anisometropic woman with stage 2 keratoconus submitted to refractive lens exchange employing SN60T5 AcrySof Toric intraocluar lens on her left eye. Phacoemulsification followed by proper lens implantation was accomplished successfully. On postoperative period, favorable refractive and visual outcomes were obtained. The use of toric intraocular lenses may b...
متن کامل