Variation of cone photoreceptor packing density with retinal eccentricity and age.
نویسندگان
چکیده
PURPOSE To study the variation of cone photoreceptor packing density across the retina in healthy subjects of different ages. METHODS High-resolution adaptive optics scanning laser ophthalmoscope (AOSLO) systems were used to systematically image the retinas of two groups of subjects of different ages. Ten younger subjects (age range, 22-35 years) and 10 older subjects (age range, 50-65 years) were tested. Strips of cone photoreceptors, approximately 12° × 1.8° long were imaged for each of the four primary retinal meridians: superior, inferior, nasal, and temporal. Cone photoreceptors within the strips were counted, and cone photoreceptor packing density was calculated. Statistical analysis (three-way ANOVA) was used to calculate the interaction for cone photoreceptor packing density between age, meridian, and eccentricity. RESULTS As expected, cone photoreceptor packing density was higher close to the fovea and decreased with increasing retinal eccentricity from 0.18 to 3.5 mm (∼0.6-12°). Older subjects had approximately 75% of the cone density at 0.18 mm (∼0.6°), and this difference decreased rapidly with eccentricity, with the two groups having similar cone photoreceptor packing densities beyond 0.5 mm retinal eccentricity on average. CONCLUSIONS Cone packing density in the living human retina decreases as a function of age within the foveal center with the largest difference being found at our most central measurement site. At all ages, the retina showed meridional difference in cone densities, with cone photoreceptor packing density decreasing faster with increasing eccentricity in the vertical dimensions than in the horizontal dimensions.
منابع مشابه
Individual variations in human cone photoreceptor packing density: variations with refractive error.
PURPOSE To measure the variation in human cone photoreceptor packing density across the retina, both within an individual and between individuals with different refractive errors. METHODS A high-resolution adaptive optics scanning laser ophthalmoscope was used to image the cones of 11 human eyes. Five subjects with emmetropia and six subjects with myopia were tested (+0.50 to -7.50 D). For ea...
متن کاملCone photoreceptor definition on adaptive optics retinal imaging
AIMS To quantitatively analyse cone photoreceptor matrices on images captured on an adaptive optics (AO) camera and assess their correlation to well-established parameters in the retinal histology literature. METHODS High resolution retinal images were acquired from 10 healthy subjects, aged 20-35 years old, using an AO camera (rtx1, Imagine Eyes, France). Left eye images were captured at 5° ...
متن کاملInterocular symmetry of parafoveal photoreceptor cone density distribution.
PURPOSE To investigate the variation and symmetry of cone density distribution along the nasal and temporal retina of fellow eyes. METHODS An adaptive optics retinal camera (rtx1; Imagine Eyes) was used to obtain images of the parafoveal cone mosaic in 20 healthy subjects. Cone density was estimated at 250, 420, 760, and 1,300 μm eccentricity from the fovea along the nasal and temporal retina...
متن کاملTechnical Factors Influencing Cone Packing Density Estimates in Adaptive Optics Flood Illuminated Retinal Images
PURPOSE To investigate the influence of various technical factors on the variation of cone packing density estimates in adaptive optics flood illuminated retinal images. METHODS Adaptive optics images of the photoreceptor mosaic were obtained in fifteen healthy subjects. The cone density and Voronoi diagrams were assessed in sampling windows of 320×320 µm, 160×160 µm and 64×64 µm at 1.5 degre...
متن کاملEccentricity dependent changes of density, spacing and packing arrangement of parafoveal cones.
PURPOSE To investigate the distribution of cone density and spacing as well as the preferred packing arrangement of the cone mosaic as a function of retinal eccentricity. METHODS An adaptive optics retinal camera (rtx1, www.imagine-eyes.com) was used to obtain images of the parafoveal cone mosaic in nineteen healthy volunteers. Cone density and spacing were estimated for each subject (both ey...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 10 شماره
صفحات -
تاریخ انتشار 2011