Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis

نویسندگان

  • Wen-Tao Zhao
  • Da-Ping Qin
  • Xiao-Gang Zhang
  • Zhi-Peng Wang
  • Zun Tong
چکیده

BACKGROUND Clinical results have shown that different vertebral heights have been restored post-augmentation of osteoporotic vertebral compression fractures (OVCFs) and the treatment results are consistent. However, no significant results regarding biomechanical effects post-augmentation have been found with different types of vertebral deformity or vertebral heights by biomechanical analysis. Therefore, the present study aimed to investigate the biomechanical effects between different vertebral heights of OVCFs before and after augmentation using three-dimensional finite element analysis. METHODS Four patients with OVCFs of T12 underwent computed tomography (CT) of the T11-L1 levels. The CT images were reconstructed as simulated three-dimensional finite-element models of the T11-L1 levels (before and after the T12 vertebra was augmented with cement). Four different kinds of vertebral height models included Genant semi-quantitative grades 0, 1, 2, and 3, which simulated unilateral augmentation. These models were assumed to represent vertical compression and flexion, left flexion, and right flexion loads, and the von Mises stresses of the T12 vertebral body were assessed under different vertebral heights before and after bone cement augmentation. RESULTS Data showed that the von Mises stresses significantly increased under four loads of OVCFs of the T12 vertebral body before the operation from grade 0 to grade 3 vertebral heights. The maximum stress of grade 3 vertebral height pre-augmentation was produced at approximately 200%, and at more than 200% for grade 0. The von Mises stresses were significantly different between different vertebral heights preoperatively. The von Mises stresses of the T12 vertebral body significantly decreased in four different loads and at different vertebral body heights (grades 0-3) after augmentation. There was no significant difference between the von Mises stresses of grade 0, 1, and 3 vertebral heights postoperatively. The von Mises stress significantly decreased between pre-augmentation and post-augmentation in T12 OVCF models of grade 0-3 vertebral heights. CONCLUSION Vertebral augmentation can sufficiently reduce von Mises stresses at different heights of OVCFs of the vertebral body, although this technique does not completely restore vertebral height to the anatomical criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Augmentation Material Stiffness on Adjacent Vertebrae after Osteoporotic Vertebroplasty Using Finite Element Analysis with Different Loading Methods.

BACKGROUND Vertebroplasty is an effective treatment for osteoporotic vertebral fractures, which are one of the most common fractures associated with osteoporosis. However, clinical observation has shown that the risk of adjacent vertebral body fractures may increase after vertebroplasty. The mechanism underlying adjacent vertebral body fracture after vertebroplasty is not clear; excessive stiff...

متن کامل

Percutaneous Vertebroplasty in Iranian Patients with Osteoporotic Vertebral Fractures

Background: Osteoporotic compression vertebral fractures are common clinical problems. In those with refractory fractures, percutaneous cement augmentation has been suggested. The aim of this study was to evaluate the functional outcome of percutaneous vertebroplasty in Iranian patients with refractory osteoporotic fractures. Methods: We retrospectively studied 37 osteoporotic fractures in 28 p...

متن کامل

An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture.

STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVES To determine if the inflatable bone tamp (tamp) restores height to compressed vertebral bodies and to compare the biomechanical properties of isolated, fractured osteoporotic vertebral bodies treated by kyphoplasty (tamp) or vertebroplasty. SUMMARY OF BACKGROUND DATA Previous biomechanical stu...

متن کامل

An ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load.

STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVE To determine if fracture reduction could be achieved by the inflatable bone tamp (tamp) in vertebral bodies under simulated physiologic loads. SUMMARY OF BACKGROUND DATA Previous ex vivo biomechanical studies showed that kyphoplasty restored vertebral body height with vertebral body endplates u...

متن کامل

A biomechanical investigation of vertebroplasty in osteoporotic compression fractures and in prophylactic vertebral reinforcement.

STUDY DESIGN Cadaveric single vertebrae were used to evaluate vertebroplasty as a prophylactic treatment and as an intervention for vertebral compression fractures. OBJECTIVE To investigate the biomechanical characteristics of prophylactic reinforcement and postfracture augmentation of cadaveric vertebrae. SUMMARY OF BACKGROUND DATA Percutaneous vertebroplasty is a treatment option for oste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018