The aims of this study were to assess the repeatability of the Emed ST4 system and identify the range of pressure values observed in the normal foot. Fifty-three healthy subjects, 17 females (32%) and 36 males (68%), were recruited. Measurements were performed on two occasions approximately 12 days apart. Peak pressure (PP), contact area (CA), contact time (CT), pressure-time integral (PTI), force-time integral (FTI) and instant of peak pressure (IPP) were recorded. The coefficient of repeatability (CR) was less than 16.9% for all 122 parameters considered. The highest areas of PP were found under the second and third metatarsal heads, with mean (S.D.) equal to 361 kPa (104) and 330 kPa (84), respectively, followed by the great toe 321 kPa (141) and heel 313 kPa (77). CA was highest under the heel at 35 cm(2) (5). The percentage CT was in the range 75-85% under the metatarsal heads, and 70% under the hallux. PTI was highest under metatarsal heads one to three and hallux. FTI was highest under the heel. Emed ST4 system was found to be repeatable. The ranges of the parameters documented can be applied in orthopaedic clinics as part of the assessment of pathological conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal pressure values and repeatability of the Emed® ST2 system.

OBJECTIVES This study was designed to assess the repeatability of the Emed® ST2 system and identify the range of pressure values observed in the normal foot. METHODS Measurements were taken from twenty-three healthy subjects, 14 females and 9 males, on two occasions 7 days apart. Begin of contact (BC), end of contact (EC), contact time (CT), peak pressure (PP), instant of peak pressure (IPP),...

متن کامل

Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...

متن کامل

The Pedar in-shoe system: repeatability and normal pressure values.

The Pedar system is one of the most commonly used systems for in-shoe pressure measurement. Good repeatability is necessary to ensure the consistency of measurements on which clinical judgements are based. In addition, there is a need to establish a range of normal in-shoe pressure values, which will help to identify abnormalities. The aim of this study was to assess the repeatability of the Pe...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Pilot study: Assessing repeatability of the EcoWalk platform resistive pressure sensors to measure plantar pressure during barefoot standing

Plantar pressure provides useful information to assess the feet’s condition. These systems have emerged as popular tools in clinical environment. These systems present errors and no compensation information is presented by the manufacturer, leading to uncertainty in the measurements. Ten healthy subjects, 5 females and 5 males, were recruited. Lateral load distribution, antero-posterior load di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gait & posture

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2008