Cough frequency monitors: can they discriminate patient from environmental coughs?

نویسندگان

  • Stefan T Kulnik
  • Natalie M Williams
  • Lalit Kalra
  • John Moxham
  • Surinder S Birring
چکیده

BACKGROUND Objective cough frequency measurements are increasingly applied in clinical research. Technological advances enable automated detection and counting of cough events from sound recordings of many hours' duration. A possible limitation of sound-based cough frequency measurement is the contamination of recordings by environmental coughs (coughs from persons other than the patient). This study aimed to investigate the accuracy of a sound-based cough monitor for detecting and discriminating patient cough from environmental cough. METHODS As part of a stroke trial (ISRCTN40298220), patients on a hospital ward underwent 15-minute recordings using the Leicester Cough Monitor (LCM), a sound-based cough monitor ('semi-automated counts'). Participants and other persons in the environment were prompted to cough. An observer present in the room recorded the number of patient and environmental coughs ('live counts'). LCM counts were also compared against a manual cough count, the most commonly used gold standard to determine accuracy ('manual sound counts' from listening to recordings), by a blinded assessor who cross-referenced timed cough events from the respective methods. Data for automated, manual and live cough counts were analyzed using agreement statistics. RESULTS On sound recordings from five patients, there were 65 patient coughs and 78 environmental coughs (manual counts). Absolute agreement for patient cough count between all three measurement methods (LCM automated, live, and manual sound counts) was high, with intra-class correlation coefficient of 0.94 [95% confidence intervals (CI): 0.74, 0.99]. The proportion of exact agreements for patient cough between LCM and manual count was 0.92, and kappa was 0.84 (95% CI: 0.75, 0.93). The LCM showed sensitivity of 0.94 (95% CI: 0.84, 0.98), specificity of 0.91 (95% CI: 0.82, 0.96), positive predictive value of 0.90 (95% CI: 0.79, 0.95) and negative predictive value of 0.95 (95% CI: 0.86, 0.98) for detecting patient coughs. CONCLUSIONS This preliminary study supports the validity of the cough monitor for detecting and discriminating patient from environmental cough. Further validation is recommended, to describe the level of accuracy with greater precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Leicester Cough Monitor: preliminary validation of an automated cough detection system in chronic cough.

Chronic cough is a common condition that presents to both primary and secondary care. Assessment and management are hampered by the absence of well-validated outcome measures. The present study comprises the validation of the Leicester Cough Monitor (LCM), an automated sound-based ambulatory cough monitor. Cough frequency was measured with the LCM and compared with coughs and other sounds count...

متن کامل

Simultaneous versus video counting of coughs in hypertonic cough challenges

BACKGROUND The coughs occurring during cough provocation tests are usually counted at the same time when the test is being conducted, i.e., simultaneously. It is unknown whether cough counting from video recording might increase the accuracy of the cough counting. During recent years, cough challenges with hypertonic aerosols have been introduced. They often provoke very frequent coughing which...

متن کامل

Establishing a gold standard for manual cough counting: video versus digital audio recordings

BACKGROUND Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. METHODS We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis...

متن کامل

The automatic recognition and counting of cough

BACKGROUND Cough recordings have been undertaken for many years but the analysis of cough frequency and the temporal relation to trigger factors have proven problematic. Because cough is episodic, data collection over many hours is required, along with real-time aural analysis which is equally time-consuming. A method has been developed for the automatic recognition and counting of coughs in so...

متن کامل

Effects of airway inflammation on cough response in the guinea pig.

We have developed a guinea pig model for cough related to allergic airway inflammation. Unanesthetized animals were exposed to capsaicin aerosols for 10 min, and cough frequency was counted during this period. The cough evaluation was performed by the following three methods: visual observation, acoustic analysis, and monitoring of pressure changes in the body chamber. These analyses clearly di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of thoracic disease

دوره 8 11  شماره 

صفحات  -

تاریخ انتشار 2016