Susceptibility Weighted MRI of Ferumoxytol at 3T and 7T in Human Brain

نویسندگان

  • J. Grinstead
  • S. Gahramanov
  • C. Varallyay
  • V. Jellus
  • E. A. Neuwelt
  • W. D. Rooney
چکیده

Introduction Susceptibility weighted imaging (SWI) is used routinely at clinical field strengths because of its high sensitivity to venous vasculature, blood products, and tissue iron content. This sensitivity is due to the magnetic susceptibility information in the phase images which are used to mask the magnitude images [1]. These susceptibility effects increase with the main magnetic field strength. Recent work [2] has focused on optimization of SWI at 7T, focusing primarily on echo time (TE) and voxel geometries, although it did not address the effects of contrast agents or consider modifying the application of the phase mask. The recent availability of Ultrasmall Superparamagnetic Iron-Oxide (USPIO; FeO) contrast agents (Ferumoxytol, AMAG Pharmaceuticals, Inc) gives another way to potentially increase the sensitivity of SWI and allow even smaller blood vessels and tissue pathology to be imaged. This contrast agent has a half life in the blood of ~14 hours, and because of its high molecular weight it does not cross the blood-brain-barrier (BBB) soon after injection even in leaky tumors, as opposed to traditional gadolinium based contrast agents. This work investigates the combination of SWI and FeO contrast agents in the study of brain tumors at 3T and 7T. Methods Eleven subjects provided informed consent before participating in this study. Data were acquired at 3T (Trio a Tim System, Siemens) using a 12channel phased array head coil and at 7T (MAGNETOM 7T, Siemens) using an 8-channel phased array head coil (Rapid Biomedical, Wurzburg, Germany). SWI parameters at 3T were TE20/TR30/FA15°, (0.6mm)x2mm and at 7T were TE12/TR26/FA15°, (0.5mm)x1.5mm voxels, iPAT2, 5min scan time. Images were acquired before contrast injection, 20 minutes after injection of 0.1 mmol/kg gadoteridol (ProHance, Bracco Diagnostics, Inc), 20 minutes after injection of 0.6 mg/kg FeO, 20 minutes after 4 mg/kg FeO, and 24 hours following 4 mg/kg FeO. The standard SWI algorithm iteratively applies the phase mask four times to enhance the contrast in the magnitude images. The effect of varying the number of iterations on image quality was investigated offline using Matlab (Mathworks, Natick, MA). Results and Discussion Figure 1 shows a comparison of the SWI minimum intensity projections (mIPs) over eight slices at 3T and 7T following FeO injection. Figure 2 shows the SWI mIPs before and after gadoteridol and FeO injections. The overall sensitivity of SWI was found to be higher at 7T as can be seen in Fig.1. Extremely small blood vessels are more visible in the 7T images. Fig. 2A-B shows that small vessels become more conspicuous after gadoteridol injection, and even more so following FeO injection (Fig. 2C) which gives a remarkable small vessel conspicuity that increases with FeO dose (Fig. 2D). The effects of FeO are still very strong after 24 hours post 4 mg/kg FeO (Fig 2E), and at a higher level than 20 minutes after the 0.6mg/kg FeO injection (Fig 2C) . It is noteworthy that the post-FeO data from 3T (Fig 1A) had greater SWI contrast than the pre-contrast data from 7T (Fig 2A), which demonstrates that FeO may be a relatively simple but powerful way to increase sensitivity for small vessel imaging at clinical field strengths. Varying the number of iterations of the phase mask had the effect of reducing the "blooming" of the larger vascular structures at the expense of decreased sensitivity to visualize extremely small vessels. It appears that letting this parameter be variable within the image viewing user interface may be warranted in cases of large magnetic susceptibility effects as seen with FeO at 7T. One of the primary reasons to use mIP images in SWI is to increase the signal-to-noise ratio (SNR), as the SNR in the single-slice SWI images is fairly low at the resolution needed for SWI at clinical field strengths. However, because of the higher SNR at 7T this was no longer a limitation and we were able to easily inspect the base SWI images. Of course, this SNR could be traded for higher resolution. Other have shown [3] that SWI offers complementary or better information than post-Gd T1 weighted imaging in detecting boundaries, blood products, and venous vessels. Tumors may take up FeO slowly, so at a time shortly after FeO administration SWI is useful primarily to improve visualization of cerebral vasculature. The very small rate constant of FeO transfer across blood vessels makes FeO potentially useful for differentiating blood pool products from the tumor vasculature, even in the presence of blood vessels that are very leaky to traditional Gd-based contrast agents. In conclusion, the increased magnetic susceptibility effects, high SNR, and low specific absorption rate (SAR) make SWI an attractive clinical application at 7T. The use of FeO contrast agents at both 3T and 7T is another powerful tool that warrants further optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma

Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance, hormonal insufficiency, and urinary incontinence that began prior to 6 years of age. 3.0T MRI re...

متن کامل

Comparison of 3T and 7T susceptibility-weighted angiography of the substantia nigra in diagnosing Parkinson disease.

BACKGROUND AND PURPOSE Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T sc...

متن کامل

Microbleed Detection in Traumatic Brain Injury at 3T and 7T: Comparing 2D and 3D Gradient-Recalled Echo (GRE) Imaging with Susceptibility-Weighted Imaging (SWI)

Methods Twenty-four patients and three controls (21 men, 6 women, mean age 33.4 years, age range 19-54) were recruited and scanned on 3T or 7T GE Excite scanners. Five TBI patients scanned at 3T received a repeat scan 1 to 12 months after the first scan, for a total of 23 scans at 3T and 9 scans at 7T. Sixteen of the patients had mild TBI (Glasgow Coma Scale (GCS) 13-15), three moderate TBI (GC...

متن کامل

Increased cortical grey matter lesion detection in multiple sclerosis with 7 Tesla MRI : a postmortem verification study 2 . 3 7 T postmortem MRI and histopathology study

The relevance of cortical grey matter pathology in multiple sclerosis has become increasingly recognised over the past decade. Unfortunately, a large part of cortical lesions remain undetected on MRI using standard field strength. In vivo studies have shown improved detection by using higher magnetic field strengths up to 7 T. So far, a systematic histopathological verification of ultrahigh-fie...

متن کامل

Iron Accumulation in Deep Cortical Layers Accounts for MRI Signal Abnormalities in ALS: Correlating 7 Tesla MRI and Pathology

Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disorder characterized by cortical and spinal motor neuron dysfunction. Routine magnetic resonance imaging (MRI) studies have previously shown hypointense signal in the motor cortex on T(2)-weighted images in some ALS patients, however, the cause of this finding is unknown. To investigate the utility of this MR signal change...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008