Characterization of the non-linear rate-dependency of QT interval in humans.
نویسندگان
چکیده
AIMS Repolarization has rate-dependent and rate-independent components. A function considering such components separately was validated in canine Purkinje fibres and applied to the QT/RR relation in humans. METHODS AND RESULTS Action potential duration (APD) was measured in Purkinje fibres during steady-state pacing at different cycle lengths (CL) and after prolonged quiescence (APD(0)). The APD/CL relationship was expressed by this function: APD=APD(max)(*)CL(S)/(CL(50)(S)+CL(S)), where APD(max) (APD extrapolated at infinite CL) is a rate-independent measure of repolarization, CL(50) (CL at which 50% of APD(max) is achieved) and S evaluates the rate dependency of APD. The same function was used to fit the QT/RR relation in 46 normal subjects (20 males, 26 females) and in 7 amiodarone-treated subjects undergoing a bicycle stress test. RR and QT (V(5)) were measured at the end of each load step; QT(c) (Bazett's formula) was obtained at rest. The APD/CL and QT/RR relations were equally well expressed by the function with high correlation coefficients (R>or=0.90). In Purkinje fibres, APD(max) was 461+/-37 ms, CL(50) was 394+/-54 ms and S was 0.98+/-0.11. APD(max) and APD(0) correlated (R=0.96) and were similar. The corresponding values in humans were: QT(max) 432+/-63 ms, RR(50) 345+/-60 ms and S 2.6+/-0.8. While QT(c) and QT(max) were longer in females, RR(50) and S were similar between genders. Amiodarone increased QT(c), QT(max) and RR(50) and decreased S. In QT(max) and QT(c) distributions generated by pooling data from treated and untreated subjects, 86% of treated subjects were correctly identified by QT(max) and 28% by QT(c). CONCLUSIONS Canine and human repolarization showed a saturating dependency on cycle length, described by the proposed function. Gender and amiodarone independently affected QT(max), RR(50) and S: therefore they might reflect specific ionic mechanisms. Finally, QT(max) identified drug-induced repolarization abnormalities in individual subjects better than QT(c).
منابع مشابه
Determination of sensitivity and specificity of QT interval in ECG of diabetic patients for ndiagnosis of cardiac autonomic neuropathy
one of the important complications of diabetes mellitus that physicians pay less attention to is diabetic autonomic neuropathy(DNA) ,especially cardiac autonomic neuropathy (CAN).this has a poor prognosis and is accompanied by sudden death risk,recently several investigations that were carried out for CAN detection ,suggested that QT-interval prolongation in these patients is an important diagn...
متن کاملChanges in QT interval before and after hemodialysis
Background: Cardiovascular mortality and morbidity are high in chronic renal failure (CRF) patients. Increased dispersion of QT intervals is known to predispose to ventricular arrhythmias and sudden cardiac death. This study was conducted to assess the effect of hemodialysis (HD) on corrected QT (QTc) intervals and their dispersions (QTd) in chronic hemodialyzed patients. Methods: Fifty-eight p...
متن کاملModeling and quantification of repolarization feature dependency on heart rate.
INTRODUCTION This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". OBJECTIVES This work aims at providing an efficient method to estimate the parameters of a non linear model including memory, previously proposed to characterize rate adaptation of repolarization indices...
متن کاملComparison of the Effect of Continuous and Interval Aerobic Training on Electrocardiogram of Active Young Girls
Aims Few studies have examined the effects of various models of aerobic training on electrocardiogram (ECG). The purpose of this study was to compare the effect of continuous and interval aerobic training on ECG of active young girls. Methods & Materials The research method was quasi-experimental and 30 active young girls were selected from among physical education students (age=17.0±0.4 yr) ...
متن کاملEffects of anxiolytic doses of ZnO nanoparticle on ECG parameters in restraint and non-restraint ovariectomized female rats
Objective(s): Based on our previous studies about nano-ZnO effects on physiological behaviors, in this study we have investigated the effects of anxiolytic doses of nano-ZnO on electrocardiogram (ECG) sings changes in the restraint and non-restraint ovariectomized (OVX) female rats. Methods: Animals (160-180 g) were divided into: control (non-OVX + saline) and OVX groups that received: s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2003