Comparison of cephalometric radiographs obtained from cone-beam computed tomography scans and conventional radiographs.

نویسندگان

  • Olivier J C van Vlijmen
  • Stefaan J Bergé
  • Gwen R J Swennen
  • Ewald M Bronkhorst
  • Christos Katsaros
  • Anne M Kuijpers-Jagtman
چکیده

PURPOSE We evaluated whether measurements on conventional cephalometric radiographs are comparable to measurements on cone-beam computed tomography (CBCT)-constructed cephalometric radiographs taken from human skulls. MATERIALS AND METHODS The CBCT scans and conventional cephalometric radiographs were made using 40 dry skulls. With I-Cat Vision software (Imaging Sciences International, Inc, Hatfield, PA), a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks, and calculate distances and angles. The same operator identified 15 landmarks on both types of cephalometric radiographs on all images 5 times with a 1-week interval. RESULTS Intraobserver reliability was good for all measurements. The reproducibility of measurements on cephalometric radiographs obtained from CBCT scans was better, compared with the reproducibility of those on conventional cephalometric radiographs. There was no clinically relevant difference between measurements on conventional and constructed cephalometric radiographs. CONCLUSIONS Measurements on CBCT-constructed cephalometric radiographs are comparable to conventional cephalometric radiographs, and are therefore suitable for longitudinal research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls.

This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from ...

متن کامل

A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls.

The aim of this study was to evaluate whether measurements performed on conventional frontal radiographs are comparable to measurements performed on three-dimensional (3D) models of human skulls derived from cone beam computed tomography (CBCT) scans and if the latter can be used in longitudinal studies. Cone beam computed tomography scans and conventional frontal cephalometric radiographs were...

متن کامل

In vivo comparison of conventional and cone beam CT synthesized cephalograms.

OBJECTIVE To compare measurements from synthesized cone-beam computed tomography (CBCT) lateral cephalograms using orthogonal and perspective projections with those from conventional cephalometric radiographs. MATERIALS AND METHODS Thirty-one patients were imaged using CBCT and conventional cephalometry. CBCT volume data were imported in Dolphin 3D. Orthogonal and perspective lateral cephalom...

متن کامل

A comparison between 2D and 3D cephalometry on CBCT scans of human skulls.

The purpose of this study was to evaluate whether measurements on conventional cephalometric radiographs are comparable with 3D measurements on 3D models of human skulls, derived from cone beam CT (CBCT) data. A CBCT scan and a conventional cephalometric radiograph were made of 40 dry skulls. Standard cephalometric software was used to identify landmarks on both the 2D images and the 3D models....

متن کامل

Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing

BACKGROUND In this study we aimed at quantifying the possible errors which may occur when assessing specific reference planes and linear derivants on cephalometric radiographs traced manually and digitally. Furthermore, we have compared the precision of the tracings according to both the two- and three-dimensional (2D and 3D respectively) techniques and between clinicians. FINDINGS We have ob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons

دوره 67 1  شماره 

صفحات  -

تاریخ انتشار 2009