Comparison of Ablation Zones among Different Tissues Using 2450-MHz Cooled-Shaft Microwave Antenna: Results in Ex Vivo Porcine Models
نویسندگان
چکیده
BACKGROUND For complete tumor ablation in different tissues, it is necessary to investigate the exact coagulation zone of microwave ablation in different tissues. The aim of this study was to compare the extent of microwave ablation zone in muscle, liver and adipose tissue in ex vivo porcine models and assess the shape of microwave coagulation zone among these tissues. MATERIALS AND METHODS Microwave ablations were performed in ex vivo porcine muscle, liver and adipose tissue using 2450-MHz cooled-shaft microwave antenna. The content of water, fat and protein in these three tissues was determined. Two power increments (40 and 80 W) and five time increments (1, 3, 5, 7, and 10 minutes) were used in this study. Diameters and shapes of the ablation zones were assessed on gross specimens. RESULTS The average percentages of water, fat and protein in these three tissues were significantly different (P < 0.001), respectively. The long-axis and short-axis diameters among these three tissues at each time-power combination were not significantly different (P > 0.05). The coagulation zones were all elliptical in muscle, liver and adipose tissue. When microwave ablation was performed in the tissue containing both muscle and adipose tissue, the coagulation zone was also elliptical. Regardless of the output power, the ellipticity index (EI) value of 1 minute treatment duration was higher than that of 10 minutes treatment duration (P < 0.05). Furthermore, the EI value did not decrease significantly when the treatment duration was more than 5 minutes (P > 0.05). CONCLUSION The extent of microwave ablation zones was not significantly different among completely different tissues. Microwave ablations with ≥ 5 minutes time duration can induce coagulation zones with clinical desirable shape. Future clinical studies are still required to determine the role of microwave ablation in different tissues.
منابع مشابه
Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury.
BACKGROUND Radiofrequency (RF) catheter ablation lesion size has been limited by the small volume of tissue directly heated by the RF electrode. Microwave (MW) energy has been proposed as an alternative energy source to generate larger lesions because of its increased volume of direct tissue heating. To further characterize MW ablation of myocardium, we studied the temperature-versus-distance p...
متن کاملUltrasound-guided percutaneous microwave ablation of benign thyroid nodules: experimental and clinical studies.
PURPOSE To obtain the treatment parameters of internally cooled microwave antenna and to evaluate the feasibility of ultrasound-guided percutaneous microwave ablation (MWA) for benign thyroid nodules. MATERIALS AND METHODS MWAs were performed by microwave antenna (16G) in ex vivo porcine liver. The lesion diameters achieved in different groups (20, 25, and 30 W for 3, 5, 7, 10, and 12 min) we...
متن کاملExperimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation
PURPOSE To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape. MATERIALS AND METHODS 108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) gl...
متن کاملRESEARCH COMMUNICATION Microwave Ablation Treatment of Liver Cancer with a 2,450- MHz Cooled-shaft Antenna: Pilot Study on Safety and Efficacy
Imaging-guided thermal ablation using different energy sources (such as RF, microwave, or laser) continues to gain favor as a minimally invasive technique for the treatment of primary and metastatic hepatic malignant tumors (Ng et al., 2005; Pacella et al., 2005; Cabassa et al., 2006; Clasen et al., 2006; Shibata et al., 2006). Regardless of the primary energy source, all of these modalities in...
متن کاملDual-slot antennas for microwave tissue heating: parametric design analysis and experimental validation.
PURPOSE Design and validate an efficient dual-slot coaxial microwave ablation antenna that produces an approximately spherical heating pattern to match the shape of most abdominal and pulmonary tumor targets. METHODS A dual-slot antenna geometry was utilized for this study. Permutations of the antenna geometry using proximal and distal slot widths from 1 to 10 mm separated by 1-20 mm were ana...