Preoperative measurement vs intraoperative aberrometry for the selection of intraocular lens sphere power in normal eyes

نویسندگان

  • James A Davison
  • Richard Potvin
چکیده

PURPOSE This study aimed to assess the value of intraoperative aberrometry (IA) in determining the intraocular lens (IOL) sphere power in eyes with no previous ocular surgery. PATIENTS AND METHODS We conducted a retrospective review of patients who underwent uncomplicated cataract surgery where standard preoperative (Preop) measurements and IA were performed. Calculated IOL sphere powers and postoperative refractions, both actual and theoretical, were compared based on the measurement method and lens type; lens types included multifocal, toric and aspheric single-vision non-toric IOLs. RESULTS A total of 160 eyes of 112 patients were analyzed. The Preop lens power calculated was the same as the IA lens power 46% of the time, though this percentage was lower for multifocal IOLs. Across all lens types, there was a statistically significant bias (chi-square test, P<0.01) toward the IA method suggesting a lower powered lens. Actual postoperative refractive errors were not statistically significantly different when categorized by measurement method. Calculated errors by measurement method showed no statistically significant differences in expected outcomes. There were 63 cases where the Preop calculation and the intraoperative aberrometer calculation differed by 0.5 D. In 56% (35/63) of these cases, the IA result was a better option, and in 44% (28/63) of cases, the Preop calculation was better; this was not statistically significantly different from random expectation (50/50, P=0.53). In the three cases where calculated powers differed by 1.5 D, there appeared to be a positive effect of adjusting the Preop power toward the IA power. CONCLUSION The use of IA for the determination of sphere power in eyes with no previous ocular surgery does not appear to improve overall expected clinical outcomes, but it may be helpful in cases where the difference between IA and Preop calculations is high.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...

متن کامل

Prediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye

Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...

متن کامل

Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens

Purpose. To evaluate outcomes in astigmatic patients implanted with the Trulign (Bausch + Lomb) toric presbyopia-correcting intraocular lens (IOL) during cataract surgery in a clinical practice setting. Methods. Retrospective study in 40 eyes (31 patients) that underwent cataract extraction and IOL implantation in a procedure using intraoperative wavefront aberrometry guidance (ORA system). End...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Comparison of Intraoperative Aberrometry, OCT-Based IOL Formula, Haigis-L, and Masket Formulae for IOL Power Calculation after Laser Vision Correction.

PURPOSE To compare the accuracy of intraoperative aberrometry technology and the Fourier-domain optical coherence tomography (OCT)-based intraocular lens (IOL) formula for IOL power calculation in eyes undergoing cataract surgery after previous laser vision correction (LVC) compared with established methods. DESIGN Retrospective consecutive case series. PARTICIPANTS Patients undergoing cata...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017