Volume measurements of normal orbital structures by computed tomographic analysis.

نویسندگان

  • G Forbes
  • D G Gehring
  • C A Gorman
  • M D Brennan
  • I T Jackson
چکیده

Computed tomographic digital data and special off-line computer graphic analysis were used to measure volumes of normal orbital soft tissue, extraocular muscle, orbital fat, and total bony orbit in vivo in 29 patients (58 orbits). The upper limits of normal for adult bony orbit, soft tissue exclusive of the globe, orbital fat, and muscle are 30.1 cm3, 20.0 cm3, 14.4 cm3, and 6.5 cm3, respectively. There are small differences in men as a group compared with women but minimal difference between right and left orbits in the same person. The accuracy of the techniques was established at 7%-8% for these orbit structural volumes in physical phantoms and in simulated silicone orbit phantoms in dry skulls. Mean values and upper limits of normal for volumes were determined in adult orbital structures for future comparison with changes due to endocrine ophthalmopathy, trauma, and congenital deformity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of orbital volume change using computed tomography in isolated orbital blowout fractures.

OBJECTIVES To measure the orbital volume of unilateral pure blowout fractures with computed tomography before and after surgery and to compare 3-dimensional (3-D) imaging systems. METHODS Twenty-four patients were evaluated with facial computed tomographic scans before and after surgery. Both the orbital volume and the displaced soft tissue volume were measured by 2 operators using 2 differen...

متن کامل

Computed Tomographic Anatomy of the Thoracic Cavity Vessels in the Rayini Goat

Objectives- To provide a reference anatomy of the thoracic cavity vessels of the Rayini goat by using Computed tomography. Design- Experimented study. Animals- Five healthy Rayini goat. Procedures- Spiral CT images (with and without contrast media) were acquired from the thoracic region perpendicular to long axis of the body. CT windows were adjusted as necessary to have optimized images of ...

متن کامل

Computer analysis of orbital fat and muscle volumes in Graves ophthalmopathy.

A technique using special computer programs and data from high-resolution computed tomographic scans has been developed that provides accurate and reproducible volume measurements for muscle and fat in the orbit. Normal values for retrobulbar fat and muscle were established in 19 adults. Nineteen patients with Graves exophthalmopathy were then studied, and a spectrum of change was found that in...

متن کامل

Comparison of computed tomographic and cytological results in evaluation of normal prostate, prostatitis and benign prostatic hyperplasia in dogs

Prostate gland can be structurally evaluated by computed tomography (CT) with taking advantages of tomographic feature and post-contrast parenchymal changes. The current examination initiated to determine association between computed tomographic and cytological results in evaluation of canine prostate. Thirty mature male dogs were included and under gone by both CT and fine needle sampling of p...

متن کامل

The lacrimal keyhole, orbital door jamb, and basin of the inferior orbital fissure. Three areas of deep bone in the lateral orbit.

OBJECTIVES To calculate the volume of bone in 3 areas of the deep lateral orbit that are available for removal in decompression surgery and to demonstrate these 3 areas within a 3-dimensional computed tomographic reconstruction of the orbit. DESIGN The 3 areas of bone in the deep lateral orbit were designated the lacrimal keyhole, the sphenoid door jamb, and the basin of the inferior orbital ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 145 1  شماره 

صفحات  -

تاریخ انتشار 1985