Concurrent and predictive validation of robotic simulator Tube 3 module
نویسندگان
چکیده
PURPOSE We previously described a new procedure specific module (Tube 3) to allow the practice of vesicourethral anastomosis after robot-assisted radical prostatectomy. Herein, we report a predetermined proficiency level of Tube 3 and preliminary validation to explore whether this new module can lead to performance improvement in the da Vinci system. MATERIALS AND METHODS Eight urology residents and three urology fellows performed the Tube 3 module 1 hour daily for 7 days. The learning curve was depicted through a scatterplot and the stable point was identified through the cumulative sum chart. Concurrent and predictive validations were performed with the da Vinci system. The mean time to complete the task and end product rating score between Tube 3 training group and no Tube 3 training group were compared. RESULTS Concerning the learning curve, about 41 repetitions comprising about 5 hours were needed to achieve this stable point when the mean time to complete Tube of 384 seconds was set as a target. With regarding to the concurrent and predictive validation, there significant differences were evident in the mean time to complete 16 needle passages and the vesicourethral anastomosis and the end product rating score. CONCLUSIONS The virtual reality (VR) simulator can yield sufficient improvement in technical performance in Tube 3 within 5 hours. The acquired proficiency can be transferable to the vesicourethral anastomosis using the da Vinci system.
منابع مشابه
Concurrent and predictive validation of a novel robotic surgery simulator: a prospective, randomized study.
PURPOSE We evaluated the concurrent and predictive validity of a novel robotic surgery simulator in a prospective, randomized study. MATERIALS AND METHODS A total of 24 robotic surgery trainees performed virtual reality exercises on the da Vinci® Skills Simulator using the da Vinci Si™ surgeon console. Baseline simulator performance was captured. Baseline live robotic performance on ex vivo a...
متن کاملSetting Benchmarks for the New User: Training on the Robotic Simulator
Background and Objectives Data showing the impact of the robotic simulator on fellowship training are limited. This study was conducted to determine whether simulator scores reflect the experience of the robotic gynecologic surgeon and to develop a simulator curriculum for trainees in gynecologic oncology. Methods All faculty and fellows in the Department of Gynecologic Oncology and Reproduct...
متن کاملNumerical Modeling of the Shear Module of Alginate Micro-Beads under the Ultrasonic Thermal Effect
The mechanical properties of microscopic particles have been a heated research object for it takes the deformation of micro-beads in the microfluidic environment into account. Sufficient knowledge on mechanical properties of micro-beads would lead to better device design and application for cell mechanics, tissue engineering, etc. The physical properties of alginate beads were examined both in ...
متن کاملSmall-Scale Robot Formation Movement Using a Simple On-Board Relative Positioning System
We explore the problem of small-scale multi-robot formation control using only an unsophisticated on-board relative positioning module. The robotic setup and module are implemented and tested in a realistic virtual simulator, using standard formation types and algorithms, with and without radio communication. The experiments and results are then replicated using the real robotic platform. Final...
متن کاملClassification of Modeling for Versatile Simulation Goals in Robotic Surgery
Simulation is common practice for surgeon training in particular for robotic surgery. This paper introduces further relevant applications of simulation that improve patient safety. Therefore, the design of a modular simulator for minimally invasive robotic surgery is presented. The authors introduce a classification of hierarchical levels of modeling details for the three aspects Application, S...
متن کامل