Randomized trial of screen-film versus full-field digital mammography with soft-copy reading in population-based screening program: follow-up and final results of Oslo II study.
نویسندگان
چکیده
PURPOSE To prospectively compare performance indicators at screen-film mammography (SFM) and full-field digital mammography (FFDM) in a population-based screening program. MATERIALS AND METHODS The regional ethics committee approved the study; informed consent was obtained from patients. Women aged 45-69 years were assigned to undergo SFM (n=16 985) or FFDM (n=6944). Two-view mammograms were interpreted by using independent double reading and a five-point rating scale for probability of cancer. Positive scores were discussed at consensus meetings before decision for recall. The group was followed up for 1.5 years (women aged 45-49 years) and 2.0 years (women aged 50-69 years) to include subsequent cancers with positive scores at baseline interpretation and to estimate interval cancer rate. Recall rates, cancer detection, positive predictive values (PPVs), sensitivity, specificity, tumor characteristics, and discordant interpretations of cancers were compared. RESULTS Recall rate was 4.2% at FFDM and 2.5% at SFM (P<.001). Cancer detection rate was 0.59% at FFDM and 0.38% at SFM (P=.02). There was no significant difference in PPVs. Median size of screening-detected invasive cancers was 14 mm at FFDM and 13 mm at SFM. Including cancers dismissed at consensus meetings, overall true-positive rate at baseline reading was 0.63% at FFDM and 0.43% at SFM (P=.04). Sensitivity was 77.4% at FFDM and 61.5% at SFM (P=.07); specificity was 96.5% and 97.9%, respectively (P<.005). Interval cancer rate was 17.4 at FFDM and 23.6 at SFM. The proportion of cancers with discordant double readings was comparable at FFDM and SFM. CONCLUSION FFDM resulted in a significantly higher cancer detection rate than did SFM. The PPVs were comparable for the two imaging modalities.
منابع مشابه
Full-field digital versus screen-film mammography: comparison within the UK breast screening program and systematic review of published data.
PURPOSE To (a) compare the performance of full-field digital mammography (FFDM), using hard-copy image reading, with that of screen-film mammography (SFM) within a UK screening program (screening once every 3 years) for women aged 50 years or older and (b) conduct a meta-analysis of published findings along with the UK data. MATERIALS AND METHODS The study complied with the UK National Health...
متن کاملQuality control for digital mammography: part II. Recommendations from the ACRIN DMIST trial.
The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652-Digital vs. Screen-Film Mammography, ACRIN (2001)]. Part I of this work described the Quality Cont...
متن کاملPatient doses from screen-film and full-field digital mammography in a population-based screening programme.
The aim of this study was to compare mean glandular dose (MGD) in all full-field digital mammography (FFDM) and screen film mammography (SFM) systems used in a national mammography screening program. MGD from 31 screening units (7 FFDM and 24 SFM), based on an average of 50 women at each screening unit, representing 12 X-ray models (6 FFDM and 6 SFM) from five different manufacturers were calcu...
متن کاملBreast cancer screening results 5 years after introduction of digital mammography in a population-based screening program.
PURPOSE To compare full-field digital mammography (FFDM) using computer-aided diagnosis (CAD) with screen-film mammography (SFM) in a population-based breast cancer screening program for initial and subsequent screening examinations. MATERIALS AND METHODS The study was approved by the regional medical ethics review board. Informed consent was not required. In a breast cancer screening facilit...
متن کاملComparison of calcification specificity in digital mammography using soft-copy display versus screen-film mammography.
OBJECTIVE The purpose of this study was to compare specificity in the interpretation of calcifications in soft-copy reviewing of digital mammograms versus hard-copy reviewing of screen-film mammograms. MATERIALS AND METHODS A total of 130 consecutive cases with calcifications (44 malignant and 86 benign) that had been evaluated with needle or surgical biopsy were collected. Both screen-film m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 244 3 شماره
صفحات -
تاریخ انتشار 2007