On Detectable and Non-detectable Structural Change
نویسنده
چکیده
A range of parameter changes in I(1) cointegrated time series are not reflected in econometric models thereof, in that many shifts are not easily detected by conventional tests. The breaks in question are changes that leave the unconditional expectations of the I(0) components unaltered. Thus, dynamics, adjustment speeds etc. may alter without detection. However, shifts in long-run means are generally noticeable. Using the VECM model class, the paper discusses such results, explains why they occur, and uses Monte Carlo experiments to illustrate the contrasting ease of detection of ‘deterministic’ and ‘stochastic’ shifts.
منابع مشابه
Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
Abstract Background: Postural instability has been identified as a potential precursor of falls in elderly subjects. Postural stability in quiet stance is commonly assessed with center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure (COP) measures in the elderly subjects. Met...
متن کاملThe evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response
ABSTRACTBackground: Although Electronic Portal imaging Devices (EPIDs) have originally developed for positioning verification, they can also be used for dosimetric purposes. In the current work, the dose response of minimum detectable thickness of a Scanning Liquid filled Ion Chamber EPID, SLIC-EPID, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was al...
متن کاملThe Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...
متن کاملIn Vitro Fertilized Embryos do not Secrete Detectable HLA-G on Day Two
Background: Pregnancy is a successful transplantation. The factors evading rejection of the fetus are poorly understood. Recently an interest has grown, in HLA-G molecules as one of these factors. Since these antigens are mainly expressed on the surface of cytotro-phoblasts that are in direct contact with maternal tissues, it has been suggested that these molecules may have a role in induction ...
متن کامل14-3-3 Protein is Detectable in Blood Serum and Fetlock Joint Synovial Fluid of High Performance Horses
Objective: To investigate whether 14-3-3 eta protein is detectable in synovial fluid and blood serum of high performance horses and to study whether any significant correlation between this and matrix metalloproteinase 1 and 3 in horse synovial fluid. Design: Clinical study. Animals: Eleven standard breed horses (seven high performances and four controls). Procedures: Blood serum and fetlock...
متن کامل