Assessment of tidal volume and thoracoabdominal motion using volume and flow-oriented incentive spirometers in healthy subjects.

نویسندگان

  • V F Parreira
  • G M Tomich
  • R R Britto
  • R F Sampaio
چکیده

The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne) and flow-oriented (Triflo II and Respirex) devices. Sixteen healthy subjects, 24 +/- 4 years, 62 +/- 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45 masculine). Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 +/- 268 vs 947 +/- 268 ml, P = 0.02) and minute ventilation (9.07 +/- 3.61 vs 7.49 +/- 2.58 l/min, P = 0.01) were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 +/- 1.24 vs 8.57 +/- 1.89 bpm). Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 +/- 0.05 vs 0.32 +/- 0.05 ml/s, P = 0.00, and 531 +/- 137 vs 606 +/- 167 ml/s, P = 0.00, respectively). Abdominal motion was larger (P < 0.05) during the use of volume-oriented devices compared to flow-oriented devices (52 +/- 11% for Coach and 50 +/- 9% for Voldyne; 43 +/- 13% for Triflo II and 44 +/- 14% for Respirex). We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volume rather than flow incentive spirometry is effective in improving chest wall expansion and abdominal displacement using optoelectronic plethysmography.

BACKGROUND Incentive spirometers are widely used in clinical practice and classified as flow-oriented (FIS) and volume-oriented (VIS). Until recently the respiratory inductive plethysmography used to evaluate the effects of incentive spirometry on chest wall mechanics presented limitations, which may explain why the impact of VIS and FIS remains poorly known. OBJECTIVE To compare the effects ...

متن کامل

[Effects of breathing exercises on breathing pattern and thoracoabdominal motion after gastroplasty].

OBJECTIVE To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. METHODS Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incenti...

متن کامل

Effect of volume-oriented versus flow-oriented incentive spirometry on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly.

BACKGROUND Aging causes physiological and functional changes that impair pulmonary function. Incentive spirometry is widely used for lung expansion, but the effects of volume-oriented incentive spirometry (VIS) versus flow-oriented incentive spirometry (FIS) on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly are poorly understood. We compared VIS a...

متن کامل

Diaphragmatic mobility in healthy subjects during incentive spirometry with a flow-oriented device and with a volume-oriented device.

OBJECTIVE To compare the diaphragmatic mobility of healthy subjects during incentive spirometry with a volume-oriented device, during incentive spirometry with a flow-oriented device, and during diaphragmatic breathing. To compare men and women in terms of diaphragmatic mobility during these three types of breathing exercises. METHODS We evaluated the pulmonary function and diaphragmatic mobi...

متن کامل

Diaphragmatic mobility in healthy subjects during incentive spirometry with a flow-oriented device and with a volume-oriented device* Mobilidade diafragmática durante espirometria de incentivo orientada a fluxo e a volume em indivíduos sadios

Objective: To compare the diaphragmatic mobility of healthy subjects during incentive spirometry with a volumeoriented device, during incentive spirometry with a flow-oriented device, and during diaphragmatic breathing. To compare men and women in terms of diaphragmatic mobility during these three types of breathing exercises. Methods: We evaluated the pulmonary function and diaphragmatic mobil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas

دوره 38 7  شماره 

صفحات  -

تاریخ انتشار 2005