Telescoping versus non-telescoping rods in the treatment of osteogenesis imperfecta.
نویسندگان
چکیده
A retrospective study was undertaken to evaluate and compare the results of telescoping (group I) versus non telescoping rods (group II) in the treatment of osteogenesis imperfecta. Thirty-three lower limb segments in ten patients were studied (14 segments in group I and 19 segments in group II). The surgical techniques of Sofield and Miller (1959) and Lang-Stevenson and Sharrard (1984) for rod insertion were used. All cases were assessed clinically regarding mobility status, growth and limb-length, refracture, and infection. They were also assessed radiologically regarding rod migration, bone outgrowing the rod, incorrect T-piece placement, breakage and bending of rods. The average duration of follow-up was 86.2 months (range: 6 to 8 years). Mobility status and bone growth were better in group I than in group II patients. The overall implant related complication rate was 28.6% in group I in comparison to 68.4% in group II. Rod migration was twice more common in group II than in group I. Bone outgrowing the rod and breakage of rods with fracture was seen in group II only. The three-year survival rate for telescoping rods was 92.9% in contrast to 68.4% for non telescoping rods. The reoperation rate was 7.2% in group I and 31.6% in group II. From this comparative study it was clear that the results were significantly better after Sheffield rods with regard to mobility status, longevity of the rod, and the frequency of complications requiring reoperations. Also most of the complications were related to the technique of rod insertion and the type of rod.
منابع مشابه
Effect of Different Distal Fixation Augmentation Methods on the Pullout Strength of Fassier-Duval Telescoping Rods.
Antegrade telescoping rods have been introduced for use in pediatric patients with osteogenesis imperfecta (OI) to decrease the incidence of long-bone fractures and to correct and prevent deformities. Recent studies have documented failures of telescoping intramedullary rods due to inadequate distal fixation. The purpose of this study was to evaluate the pullout strength of distal fixation of t...
متن کاملEffects of a telescopic intramedullary rod for treating patients with osteogenesis imperfecta of the femur
Purpose To introduce a new model of telescopic intramedullary rod (TIR), evaluate its effects on treating patients presenting with moderate and severe osteogenesis imperfecta (OI) and to compare the findings with those of other telescopic rods. Methods A total of 21 patients (nine girls and 12 boys; mean age at first operation, 6.6 years, 1.52 to 13.18) who underwent 52 femoral operations wer...
متن کاملInterlocking telescopic rod for patients with osteogenesis imperfecta.
BACKGROUND Intramedullary fixation with use of a telescopic rod with a T-piece is one of the standard methods for long-bone stabilization in growing children with osteogenesis imperfecta. However, installation and removal of this device can cause substantial damage to the distal joint, which limits its use, especially in the tibia. We devised a modification of the telescopic rod system--the int...
متن کاملTelescoped trajectories from alcohol initiation to disorder in children of alcoholic parents.
The current study tested whether and why children of alcoholics (COAs) showed telescoped (adolescent) drinking initiation-to-disorder trajectories as compared with non-COAs. Using longitudinal data from a community-based sample, the authors confirmed through survival analyses that COAs progressed more quickly from initial adolescent alcohol use to the onset of disorder than do matched controls....
متن کاملComparison of Two Treatment Methods “One Shot” and “Sequential” on Reduction the Level of Hemoglobin in Patients with Percutaneous Nephrolithotripsy in Al Zahra Hospital in 2012–2013
BACKGROUND Access dilation is the most important part of percutaneous nephrolithotripsy (PCNL) that is done by different methods, especially metal telescoping and one shot. In this study, two different methods of access dilation one shot and telescoping were compared. MATERIALS AND METHODS In observational cross-sectional study, 240 patients who were a candidate for PCNL were selected and ran...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 75 2 شماره
صفحات -
تاریخ انتشار 2009