Optical emission spectroscopy at the large RF driven negative ion test facility ELISE: instrumental setup and first results.

نویسندگان

  • D Wünderlich
  • U Fantz
  • P Franzen
  • R Riedl
  • F Bonomo
چکیده

One of the main topics to be investigated at the recently launched large (A(source) = 1.0 × 0.9 m(2)) ITER relevant RF driven negative ion test facility ELISE (Extraction from a Large Ion Source Experiment) is the connection between the homogeneity of the plasma parameters close to the extraction system and the homogeneity of the extracted negative hydrogen ion beam. While several diagnostics techniques are available for measuring the beam homogeneity, the plasma parameters are determined by optical emission spectroscopy (OES) solely. First OES measurements close to the extraction system show that without magnetic filter field the vertical profile of the plasma emission is more or less symmetric, with maxima of the emission representing the projection of the plasma generation volumes, and a distinct minimum in between. The profile changes with the strength of the magnetic filter field but under all circumstances the plasma emission in ELISE is much more homogeneous compared to the smaller IPP prototype sources. Planned after this successful demonstration of the ELISE OES system is to combine OES with tomography in order to determine locally resolved values for the plasma parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Installation of spectrally selective imaging system in RF negative ion source.

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (Hα) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupl...

متن کامل

Towards 20 A negative hydrogen ion beams for up to 1 hour: Achievements of the ELISE test facility

The large-scale RF-driven ion source of the test facility ELISE is aimed to deliver an accelerated ion current of 20 A D ̅ (23 A H ̅) with an extracted electron-to-ion ratio below one for up to one hour. Since the first plasma pulses for 20 s in volume operation in Early 2013, followed by caesiation of the ion source, substantial progress has been achieved in extending the pulse length and the RF...

متن کامل

Physical Performance Analysis And The Progress Of The Development Of The Negative Ion RF Source For The ITER NBI System

For heating and current drive the neutral beam injection system for ITER requires a 1 MeV deuterium beam for up to 1 h pulse length. In order to inject the required 17 MW the large area source (1.9m x 0.9m) has to deliver 40 A of negative ion current at the specified source pressure of 0.3 Pa. In 2007 the IPP RF driven negative hydrogen ion source was chosen as the new reference source for the ...

متن کامل

Overview of diagnostics on ITER neutral beam test facility

ITER operation relies on heating neutral beam injectors (HNB) based on negative ion deuterium beams accelerated at 1 MeV, with up to one hour 17 MW power, uniform intensity and low divergence. A neutral beam test facility is being built at Consorzio RFX to demonstrate the feasibility of a prototype injector with such demanding specifications and to optimize its performances. It comprises SPIDER...

متن کامل

Size Scaling of Negative Hydrogen Ion Sources for Fusion

The RF-driven negative hydrogen ion source (H , D ) for the international fusion experiment ITER has a width of 0.9 m and a height of 1.9 m and is based on a scale prototype source being in operation at the IPP test facilities BATMAN and MANITU for many years. Among the challenges to meet the required parameters in a caesiated source at a source pressure of 0.3 Pa or less is the challenge in si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 84 9  شماره 

صفحات  -

تاریخ انتشار 2013