Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

نویسنده

  • P. F. Bloser
چکیده

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mounted in a “flip-chip” fashion on a printed circuit board carrier card; the detectors will be placed 0.3 mm apart in a tiled configuration such that the pixel pitch is preserved across both crystals. One detector is eV Products high-pressure Bridgman CZT, and the other is IMARAD horizontal Bridgman material. Both detectors are read out by a 32-channel VA-TA ASIC controlled by a PC/104 single-board computer. A passive shield/collimator surrounded by plastic scintillator surrounds the detectors on five sides and provides a ∼ 45◦ field of view. The background spectrum recorded by this instrument will be compared to that measured by a single-element CZT detector (10 mm × 10 mm × 2 mm high-pressure Bridgman material from eV Products) fitted with the same passive/plastic collimator but including an active BGO shield to the rear. This detector has been previously flown by us completely shielded by a passive cover. We describe preliminary laboratory results for the various systems, discuss initial background simulations, and describe our plans for balloon flight tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction and Testing of a Pixellated CZT Detector and Shield for a Hard X-ray Astronomy Balloon Flight

We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm detectors were fabricated, one out of standard eV Products high-pressure Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned with a 4 × 4 array o...

متن کامل

The InFOCμS Hard X-ray Telescope: Pixellated CZT Detector/Shield Performance and Flight Results

The CZT detector on the InFOCμS hard X-ray telescope is a pixellated solid-state device capable of imaging spectroscopy by measuring the position and energy of each incoming photon. The detector sits at the focal point of an 8m focal length multilayered grazing incidence X-ray mirror which has significant effective area between 20–40 keV. The detector has an energy resolution of 4.0 keV at 32 k...

متن کامل

CZT in Space Based Hard X-ray Astronomy: Background Predictions for EXIST

One of the key aspects of a detector material for space-borne hard X-ray and gamma-ray telescopes is the rate of prompt and delayed background events generated inside the material by charged and neutral particles striking the detector. These particles are Cosmic Rays, particles trapped in Earth’s magnetic field, and secondaries from Cosmic Ray interacting with the atmosphere and the spacecraft....

متن کامل

Prototype Imaging Cd - Zn - Te Array Detector

We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture telescopes with response extending over the energy range ∼ 10 − 600 keV. The coded aperture imaging configuration requires only relatively large area pixels (1...

متن کامل

CZT imaging detectors for ProtoEXIST

We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999