Jet and ultrasonic nebuliser output: use of a new method for direct measurement of aerosol output.

نویسندگان

  • J H Dennis
  • S C Stenton
  • J R Beach
  • A J Avery
  • E H Walters
  • D J Hendrick
چکیده

Output from jet nebulisers is calibrated traditionally by weighing them before and after nebulisation, but the assumption that the weight difference is a close measure of aerosol generation could be invalidated by the concomitant process of evaporation. A method has been developed for measuring aerosol output directly by using a solute (fluoride) tracer and aerosol impaction, and this has been compared with the traditional weight loss method for two Wright, six Turbo, and four Micro-Cirrus jet nebulisers and two Microinhaler ultrasonic nebulisers. The weight loss method overestimated true aerosol output for all jet nebulisers. The mean aerosol content, expressed as a percentage of the total weight loss, varied from as little as 15% for the Wright jet nebulisers to 54% (range 45-61%) for the Turbo and Micro-Cirrus jet nebulisers under the operating conditions used. In contrast, there was no discrepancy between weight loss and aerosol output for the ultrasonic nebulisers. These findings, along with evidence of both concentrating and cooling effects from jet nebulisation, confirm that total output from jet nebulisers contains two distinct fractions, vapour and aerosol. The vapour fraction, but not the aerosol fraction, was greatly influenced by reservoir temperature within the nebuliser; so the ratio of aerosol output to total weight loss varied considerably with temperature. It is concluded that weight loss is an inappropriate method of calibrating jet nebuliser aerosol output, and that this should be measured directly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease.

AIMS To compare the efficacy of salbutamol delivered by metered dose inhaler (MDI), jet nebuliser, and ultrasonic nebuliser in ventilated infants with chronic lung disease. METHODS Twenty preterm ventilated infants with chronic lung disease were enrolled in two studies. In study 1 (n = 10), each infant was given 200 micrograms of salbutamol at 4 hour intervals and in random sequence from a me...

متن کامل

Nebuliser therapy in childhood.

Jet and ultrasonic nebulisers continue to be of medications and this may reduce the deposition of the drug in the periphery of the lungs. The value in childhood. Nebulised therapy provides a portal of entry for systemic drug treatment effect of crying on aerosol deposition is not known. as well as for the direct treatment of respiratory diseases. Work by Collis has focused attention on the tota...

متن کامل

Evaluation of jet nebulisers for use with gentamicin solution.

Recently nebulised antibiotics (gentamicin and carbenicillin) have been used successfully to treat respiratory tract infection in patients with cystic fibrosis. No information exists, however, on the choice of nebuliser or the ideal mode of operation with antibiotic solutions, which are often viscous. The aerosol output, droplet size, and nebulisation time were assessed for four common brands o...

متن کامل

Differences in aerosol output and airways responsiveness between the DeVilbiss 40 and 45 hand held nebulisers.

BACKGROUND The DeVilbiss 40 glass hand held nebulisers have been widely used for airways responsiveness testing in epidemiological surveys of asthma. These nebulisers have been superseded in some recent studies by the DeVilbiss 45 plastic hand held nebulisers with the assumption that they are interchangeable. This study compared the aerosol outputs of the DeVilbiss 40 and DeVilbiss 45 nebuliser...

متن کامل

Nebulisation of surfactants in an animal model of neonatal respiratory distress.

AIMS To evaluate pulmonary deposition and gas exchange following nebulisation of two surfactants by either a jet or an ultrasonic nebuliser. METHOD After bronchoalveolar lavage (BAL), 19 rabbits were ventilated in four groups. Group A1 (n = 5) and A2 (n = 6) received Technetium-99m labelled Exosurf, and groups B1 (n = 4) and B2 (n = 4) received radiolabelled Survanta. Groups A1 and B1 receive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 45 10  شماره 

صفحات  -

تاریخ انتشار 1990