Reducing bladder artifacts in clinical pelvic SPECT images.
نویسندگان
چکیده
UNLABELLED SPECT imaging of the pelvis is hampered by the presence of bladder artifacts, which render up to 20% of the images unreadable. The artifacts are caused by the high level of activity in the bladder and by the change in activity level as the bladder fills during data acquisition. The changing activity, together with the inhomogeneous attenuation of the pelvis, leads to inconsistencies in the projections and consequently artifacts when the data are reconstructed with filtered backprojection (FBP). dSPECT is an iterative algorithm that permits the reconstruction of dynamic SPECT images from a single, slow-rotation SPECT data acquisition. The reconstruction algorithm incorporates attenuation correction (AC) and changing tracer distributions and has been shown to reduce bladder artifacts in simulated data. In this study, we showed that dSPECT is effective at removing bladder artifacts from clinically acquired pelvic bone SPECT images. METHODS Data from 20 patient volunteers were reconstructed using FBP, rescaled block-iterative reconstruction (RBI) without AC, RBI with AC, and dSPECT. AC was based on patient-specific attenuation maps acquired with a (153)Gd scanning line-source transmission system. For dSPECT, 16 time frames (4 projections/head/frame) were reconstructed and then summed to produce the final image. Artifact-to-bone contrast was compared, and image quality was subjectively assessed. RESULTS Compared with FBP, RBI without AC significantly reduced (P = 0.008) the streak artifact. Both dSPECT and RBI with AC further significantly reduced (P < 0.001) the streak artifact and also improved the uniformity and symmetry of bone tracer-uptake. RBI with AC and dSPECT produced equivalent images if the change in bladder activity during acquisition was modest; however, with large changes in the activity (>100%), RBI with AC did not completely remove the artifact. In that situation, dSPECT produced additional reductions in streak-to-bone contrast. CONCLUSION Of the methods considered, dSPECT is the most effective at removing bladder artifacts in clinical pelvic SPECT.
منابع مشابه
Diagnostic dilemma of ectopic pelvic kidney in planar skeletal and renal cortical scintigraphy resolved by SPECT/CT
We present a 55-year old male patient who was subjected to whole body skeletal scintigraphy for metastatic work up of urinary bladder cancer. Whole body 99mTc-methylene diphosphonate (MDP) skeletal scintigraphy was performed. That revealed no skeletal metastasis in the entire body skeleton and normally visualized left kidney with empty right renal fossa. Additionally tracer activity ...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملAssessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]
Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملAgenesis of the pubic symphysis detected with SPECT-CT.
The pelvis is composed of 3 paired bones (ischiac, pubic and iliac bones) and the sacrum. Any part of the pelvis can be congeni tally absent, but the sacrum is the most commonly affected. The absence can be partial or complete; unilateral or bilateral and can occur in an isolated fashion or be part of a malformation syndrome. A 99m Tc Methylene Diphosphonate (MDP) bone scan was performed in a 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 45 8 شماره
صفحات -
تاریخ انتشار 2004