High Sensitivity Optically Pumped Quantum Magnetometer

نویسندگان

  • Valentina Tiporlini
  • Kamal Alameh
چکیده

Quantum magnetometers based on optical pumping can achieve sensitivity as high as what SQUID-based devices can attain. In this paper, we discuss the principle of operation and the optimal design of an optically pumped quantum magnetometer. The ultimate intrinsic sensitivity is calculated showing that optimal performance of the magnetometer is attained with an optical pump power of 20 μW and an operation temperature of 48°C. Results show that the ultimate intrinsic sensitivity of the quantum magnetometer that can be achieved is 327 fT/Hz(½) over a bandwidth of 26 Hz and that this sensitivity drops to 130 pT/Hz(½) in the presence of environmental noise. The quantum magnetometer is shown to be capable of detecting a sinusoidal magnetic field of amplitude as low as 15 pT oscillating at 25 Hz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Sample Rate Optically Pumped Helium Magnetometer

Optically pumped helium magnetometers are important instruments whichhave many applications in military, mass spectroscopy and space applications. In thispaper, the working principles of helium magnetometers have been explained. There isalso an introduction of a new method for finding the resonant frequency, which hasadvantages to the typical method such as more sample r...

متن کامل

An Optically Pumped Magnetometer Working in the Light-Shift Dispersed Mz Mode

We present an optically pumped magnetometer working in a new operational mode-the light-shift dispersed Mz (LSD-Mz) mode. It is realized combining various features; (1) high power off-resonant optical pumping; (2) Mz configuration, where pumping light and magnetic field of interest are oriented parallel to each other; (3) use of small alkali metal vapor cells of identical properties in integrat...

متن کامل

Investigation of the intrinsic sensitivity of a He/Cs magnetometer

We report on extensive studies on the intrinsic sensitivity of a combined He/Cs magnetometer. The magnetometer relies on the detection of the free spin precession of nuclear spin polarized He by optically pumped cesium magnetometers. We characterize the relevant processes involved in the detection and quantify their impact on the total sensitivity of the magnetometer. An expression is derived t...

متن کامل

Low-noise high-density alkali-metal scalar magnetometer

We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below 10 fT Hz−1/2, fractional field sensitivity below 10−9 Hz−1/2, and an active measurement volume of about 1.5 cm3. We show...

متن کامل

A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers

Advances in the field of quantum sensing mean that magnetic field sensors, operating at room temperature, are now able to achieve sensitivity similar to that of cryogenically cooled devices (SQUIDs). This means that room temperature magnetoencephalography (MEG), with a greatly increased flexibility of sensor placement can now be considered. Further, these new sensors can be placed directly on t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013