The Bispectral Index in children: comparing isoflurane and halothane.
نویسندگان
چکیده
BACKGROUND The Bispectral Index (BIS) has been calibrated for several general anaesthetic agents including isoflurane. Halothane is still used in paediatric anaesthesia. Compared with other volatile anaesthetics, halothane has a different receptor affinity and differing effects on the EEG. There are limited data evaluating the BIS with halothane. We set out to compare the BIS using halothane and isoflurane at a clinically relevant equipotent concentration (1 MAC) and at a reproducible measure of anaesthetic effect (awakening). METHODS Forty children aged between 2 and 15 yr were enrolled in a masked randomized trial-20 in each group. Anaesthesia was induced with sevoflurane or propofol. Either halothane or isoflurane were given to obtain an end-tidal concentration of 1 MAC for 15 min. The BIS was then recorded. The BIS was also recorded at awakening. Values (mean (SD)) were compared with a t test. RESULTS At 1 MAC the BIS for halothane was significantly greater than isoflurane (56.5 (8.1) vs 35.9 (8.5), P<0.0001). At awakening there was no significant difference (BIS halothane; 81.1 (11.9), BIS isoflurane; 82.5 (16.4)). The difference in means at awakening was 1.4 (95% CI -8.2 to 11.1). CONCLUSIONS At equipotent concentrations of halothane and isoflurane BIS valves were significantly greater with halothane. At awakening the BIS values were equivalent for each agent. This finding is consistent with the BIS being more affected by the agent used at higher concentrations of anaesthetic. The BIS must be interpreted with caution when using halothane.
منابع مشابه
The bispectral index system in pediatrics--is it related to the end-tidal concentration of inhalation anesthetics?
UNLABELLED BACKGROUND AND GOAL OF STUDY: Bispectral Index (BIS) has been used in adults to measure depth of anesthesia using various protocols. Though less investigated in children, there is growing evidence that bispectral index seems adequately calibrated for monitoring the depth of isoflurane and sevoflurane anesthesia in pediatric patients. A range of BIS scores (40-60) has been seen to be ...
متن کاملThe performance of Bispectral Index in children during equi-MAC halothane vs. sevoflurane anaesthesia.
BACKGROUND AND OBJECTIVE The reliability of the Bispectral Index for evaluating and monitoring the depth of general anaesthesia in children is not as great as for that in adults. Therefore we analysed Bispectral Index performance in children by comparing changes in Bispectral Index values during a standardized and equipotent anaesthetic regimen using either halothane or sevoflurane for the indu...
متن کاملQualitative and Quantitative Characteristics of the Electroencephalogram in Normal Horses during Administration of Inhaled Anesthesia
BACKGROUND The effects of anesthesia on the equine electroencephalogram (EEG) after administration of various drugs for sedation, induction, and maintenance are known, but not that the effect of inhaled anesthetics alone for EEG recording. OBJECTIVE To determine the effects of isoflurane and halothane, administered as single agents at multiple levels, on the EEG and quantitative EEG (qEEG) of...
متن کاملCardiovascular effects of sevoflurane, isoflurane, halothane, and fentanyl-midazolam in children with congenital heart disease: an echocardiographic study of myocardial contractility and hemodynamics.
BACKGROUND The cardiovascular effects of halogenated anesthetic agents in children with normal hearts have been studied, but data in children with cardiac disease are limited. This study compared the effects of halothane, isoflurane, sevoflurane, and fentanyl-midazolam on systemic and pulmonary hemodynamics and myocardial contractility in patients with congenital heart disease. METHODS Fifty-...
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 92 1 شماره
صفحات -
تاریخ انتشار 2004