Evaluation of 99mTc-succimer dosing in pediatric patients.

نویسندگان

  • Wendy Galbraith
  • Anthony Nguyen
  • Donald L Harrison
  • Xinlian Chen
  • Katie Talley
چکیده

UNLABELLED Balancing image quality with radiation dose is a goal with every diagnostic procedure requiring radiation. Our institution compared the dosing of (99m)Tc-labeled succimer, commonly referred to as dimercaptosuccinic acid ((99m)Tc-DMSA), to pediatric patients using 2 methods of calculation, body surface area (BSA, the method we used from 2009 to 2010) and body weight (BW, the method we used in 2011). METHODS A retrospective study was conducted in a 230-bed inpatient, tertiary-care academic pediatric hospital to obtain objective data on patients under the age of 17 y who received a renal nuclear medicine procedure with (99m)Tc-DMSA using a 300,000-count parallel image and four 150,000-count pinhole images. Data collection included patient age, sex, height, weight, calculated activity, assayed activity, administered activity, residual syringe activity, imaging time, and notable patient or equipment factors affecting the procedure. RESULTS Calculated activities based on BSA were higher than calculated activities based on BW. (99m)Tc-DMSA adsorption to the plastic syringes was significant, with a range of 3%-82%. Because of the adsorption, an average of 23.7 MBq (SD, ±31 MBq) was added to the patients' calculated dose when the order was placed. Therefore, assayed activities were significantly higher than calculated activities in both groups. Administered activity correlations to BSA and BW calculations were 0.75 and 0.83, respectively. Administered activities from BSA and BW groups were outside the American College of Radiology (ACR)-recommended guidelines 59% and 45% of the time, respectively. Overall, children less than 2 y old were above the ACR recommendations 80% of the time. There was a poor correlation between administered activity and total imaging time (r = 0.23). Average imaging time overall for 5 planar views was 14.8 min (±7.1 min). Patients receiving less than the ACR-recommended administered activities (<1.85 MBq/kg) had an average increase in imaging time of 4.5 min (±3.4 min). CONCLUSION The activity administered to patients was significantly affected by the amount of (99m)Tc-DMSA activity adsorbed to the syringe. Syringe residual should be considered when standardizing (99m)Tc-DMSA imaging protocols and calculating patient dose. Although (99m)Tc-DMSA adsorption was variable, the administered activities correlated with calculated activities. In all but one of our patients, the total imaging time was far less than recommended by the ACR and European Association of Nuclear Medicine guidelines. The study indicates that using the BW calculation of 3.7 MBq/kg resulted in a range of administered activity of 1.85-2.59 MBq/kg. (99m)Tc-DMSA dosing of 3.7 MBq/kg for pinhole imaging should be appropriate for most studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of diuretic renography in the evaluation of obstructed hydronephrosis after pediatric pyeloplasty.

BACKGROUND The purpose of this study was to clarify the value of renal drainage half-time in the evaluation of pediatric hydronephrosis after dismembered pyeloplasty. METHODS We reviewed the records of 30 children who underwent dismembered pyeloplasty for unilateral ureteropelvic junction obstruction with no other associated urological abnormality. The follow-up duration was more than 5 years...

متن کامل

A Prospective Study to Assess Vancomycin Serum Concentrations in Pediatric Patients with Current Dosing Guidelines

Concerns about increasing bacterial resistance to vancomycin, have caused the adult treatment guidelines to recommend higher trough concentrations based on the type and location of infectious disease. Although these recommendations are not specific to children, the values can be extrapolated. This prospective study was designed to evaluate efficacy of current vancomycin dosing recommendations t...

متن کامل

A Prospective Study to Assess Vancomycin Serum Concentrations in Pediatric Patients with Current Dosing Guidelines

Concerns about increasing bacterial resistance to vancomycin, have caused the adult treatment guidelines to recommend higher trough concentrations based on the type and location of infectious disease. Although these recommendations are not specific to children, the values can be extrapolated. This prospective study was designed to evaluate efficacy of current vancomycin dosing recommendations t...

متن کامل

Calyceal plication with pyeloplasty in the treatment of giant hydronephrosis in children.

The relief of obstruction alone is frequently not sufficient to ensure renal salvage in giant hydronephrosis. We report on our experience with plication of the renal calyces used as an adjunct to dismembered pyeloplasty in patients with giant hydronephrosis. We describe the operative technique and outcomes in ten children after a follow-up period of six months. Ten patients (six girls and four ...

متن کامل

تخمین دوز جذبی ناشی از رادیوداروی 99mTc-DMSA در بیماران کودک تحت اسکن کلیه با استفاده از نرم‌افزار MIRDose و با بکارگیری روش ترکیبی پلنار SPECT

Introduction: 99mTc&ndash;Dimercaptosuccinic Acid (DMSA) as evaluation of pediatric genitourinary abnormalities has an important role in pediatric nuclear medicine. The aim of this study was to estimate organs absorbed dose for children injected by 99mTc DMSA using MIRDOSE software and hybrid planar/SPECT method. Methods: After injection of 99mTc-DMSA, ten children with genitourinary abnorma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2013