TIROS 111 RADIATION MEASUREMENTS AND SOME DlABATlC PROPERTIES OF THE ATMOSPHERE * PAUL

نویسنده

  • A. DAVIS
چکیده

A basic objective of this study was t o evaluate the applicability of medium-resolution satellite radiation measurements to assessments of the diabatic heating and cooling within the atmosphere. Data from portions of TIROS I11 orbital passes in mid-July 1961 and concurrent conventional data were examined over a 4-by-4-degree grid scale. Computations, appropriate to analyzed cloud conditions for each grid block, included the outgoing long-wave flux, the infrared radiational cooling, the t,otal radiational cooling (including solar absorption in the atmosphere), and the total potential energy. In addition, simple relative estimates were made of the latent heat released and the average boundary heat flus into the atmosphere. Results show that, for nadir angles less than about 45 deg., the unaltered Channel 2 temperature is proportional to the computed outgoing long-wave flux and is related to the average cloudiness in each grid block. The Channel 2 temperature has a higher positive correlation with the total radiational cooling (long-wave and shortwave) in t h e atmosphere than with the long-wave cooling alone. The relative heating from the distributions of net radiation and precipitation are correlated in the same sense to the Channel 2 temperature, but the relative boundary heat flux is correlated in the opposite sense. Unaltered Channel 3 fluxes show a general relationship t o atmospheric solar absorption rates and to a cloudiness parameter for the grid scale. Some slight generation of eddy potential energy was suggested by the analyses of the differential diabatic cooling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Nd: Yag Laser Radiation Effects on Ti6Al4V Physico-Chemical Properties: An In Vivo Study

The effect of a Nd: YAG laser (1064 nm) has been studied on Ti6Al4V alloy in terms of optical and physical parameters for biomedical applications. The superior surface microhardness hardness (i.e. 377 VHN) is attributed to grain refinement associated with laser melting and rapid solidification. The electrochemical property, mainly pitting corrosion resistance, has been carried out in Hanks salt...

متن کامل

Evaluation of Ferrous-Agarose-Xylenol Gel Properties in Radiation Dosimetry

Background: Over recent decades, modern protocols of external beam radioÂ‌therapy and radiation techniques such as intensity-modulated radiotherapy (IMRT) have been developed. These methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3D dosimetry system that has high sensitivity and is capable of measuring and verifying the complex...

متن کامل

Comparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar

Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of rado...

متن کامل

Study of gamma rays shielding parameters of some building materials used in Sudan

Background: This study investigated the γ-rays shielding properties of some building materials in Sudan has been investigated. Materials and Methods: Photons attenuation coefficients and half value layer (HVL) were experimented using Cs-137 and Co-60 sources.  The measurements were performed to gauge the intensity of radiation when performed unshielded, the specific thickness of selected sample...

متن کامل

Photon Dosimetry Quality Audit of Radiotherapy Centers in Iran: SSDL's On-Site Visit Program During 2007-2017

Introduction: A dosimetric audit is a quality assurance process (QA) that allows the accuracy of dosimetric and geometric precision to accurately control the delivery of doses. They can be used to evaluate the accuracy of radiation delivery at different radiotherapy centers. Differences in prescriptive doses, depending on the severity of the differences, have potential conseque...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1965