Biotribological behavior of Ag-ZrCxN1-x coatings against UHMWPE for joint prostheses devices.

نویسندگان

  • S Calderon V
  • J C Sánchez-López
  • A Cavaleiro
  • S Carvalho
چکیده

This study aims to evaluate the structural, mechanical and tribological properties of zirconium carbonitrides (ZrCxN1-x) coatings with embedded silver nanoparticles, produced with the intention of achieving a material with enhanced multi-functional properties, including mechanical strength, corrosion resistance, tribological performance and antibacterial behavior suitable for their use in joint prostheses. The coatings were deposited by direct current (DC) reactive magnetron sputtering onto 316 L stainless steel, changing the silver content from 0 to 20 at% by modifying the current density applied to the targets. Different nitrogen and acetylene gas fluxes were used as reactive gases. The coatings revealed different mixtures of crystalline ZrCxN1-x, silver nanoparticles and amorphous carbon phases. The hardness of the films was found to be mainly controlled by the ratio between the hard (ZrCxN1-x) and soft (Ag and amorphous carbon) phases in the films, fluctuating between 7.4 and 20.4 GPa. The coefficient of friction, measured against ultra-high molecular weight polyethylene (UHMWPE) in Hank's balanced salt solution with 10 gL(-1) albumin, is governed by the surface roughness and hardness. The UHMWPE wear rates were in the same order of magnitude (between 1.4 and 2.0 × 10(-6)mm(3)N(-1)m(-1)), justified by the effect of the protective layer of albumin formed during the tests. The small differences were due to the hydrophobic/hydrophilic character of the surface, as well as to the silver content.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antibacterial and biological characteristics of silver containing and strontium doped plasma sprayed hydroxyapatite coatings.

Infection in primary total joint prostheses is estimated to occur in up to 3% of all surgery. As a measure to improve the antimicrobial properties of implant materials silver (Ag) was incorporated into plasma sprayed hydroxyapatite (HA) coatings. To offset potential cytotoxic effects of Ag in the coatings strontium (Sr) was also added as a binary dopant. HA powder was doped with 2.0 wt.% Ag(2)O...

متن کامل

Potential for adhesive wear in friction couples of UHMWPE running against oxidized zirconium, titanium nitride coatings, and cobalt-chromium alloys.

The classical wear mechanisms abrasion, fatigue, and adhesion are the most frequent causes of surface changes of ultra high molecular weight polyethylene (UHMWPE) in artificial joints. The counterpart material has a strong influence on the wear and friction behavior of artificial joints due to its abrasive properties and adhesive interaction with UHMWPE. The formation of a transfer layer on the...

متن کامل

Influence of albumin on the tribological behavior of Ag-Ti (C, N) thin films for orthopedic implants.

With the increase of elderly population and the health problems arising nowadays, such as cancer, knee and hip joint prostheses are widely used worldwide. It is estimated that 20% of hip replacement surgeries simply fail after 5years, due to wear loosening, instability and infection. In this paper it is reported the study of advanced materials with the ability to overcome some of these drawback...

متن کامل

Biocompatibility evaluation of DLC-coated Si3N4 substrates for biomedical applications

DLC coatings are of enormous interest for biotribological applications due to their biocompatibility, auto-lubricious, and non-stick properties. The most demanding implant is the hip joint. Alternative materials to metal alloys are being increasingly investigated aiming low wear debris volume, in any case innocuous wear particles. Silicon nitride (Si3N4) ceramics are light, tough, mechanical re...

متن کامل

Microscale wear behavior and crosslinking of PEG-like coatings for total hip replacements

The predominant cause of late-state failure of total hip replacements is wear-mediated osteolysis caused by wear particles that originate from the ultrahigh molecular weight polyethylene (UHMWPE) acetabular cup surface. One strategy for reducing wear particle formation from UHMWPE is to modify the surface with a hydrophilic coating to increase lubrication from synovial fluid. This study focuses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2015