Reproducibility of oxidative stress biomarkers in breath condensate: are they reliable?
نویسنده
چکیده
In this issue of the European Respiratory Journal, VAN HOYDONCK et al. [1] report a study about the reproducibility of oxidative stress biomarkers, such as hydrogen peroxide (H 2 O 2) and 8-isoprostane (a member of the F 2-isoprostane class) in nonconcentrated exhaled breath condensate (EBC) obtained from healthy male smokers. The aim of their study was to identify whether these biomarkers could reproducibly be measured on different days of collection to enable identification of a susceptible population to lung diseases and monitoring of disease severity. The authors collected the EBC samples at three time points within 1 week (day 0, day 3 or 4, day 7) from each healthy smoker. Their major findings were: 1) H 2 O 2 and 8-isoprostane were detected in only 47% and 36% of all EBC samples, respectively; 2) only three of 12 smokers had detectable 8-isoprostane concentrations on all three occasions (mean 4.6 pg?mL-1 ; range 3.9–7.7 pg?mL-1), whereas H 2 O 2 was not detected on all three occasions in any of the smokers within 1 week; and 3) 8-isoprostane and H 2 O 2 concentrations were below the limit of detection in many samples (v3.9 pg?mL-1 for 8-isoprostane and 0.31 mM for H 2 O 2). They concluded that the levels of H 2 O 2 and 8-isoprostane could not be reproducibly assessed in the EBC of healthy smokers because of their low concentration and/or the lack of sensitivity/specificity of the available assays. The other major factors that may affect the reproducibility would include intra-and inter-individual variability, sampling time and variability in dilution of respiratory droplets by water vapour [2]. The findings described in this study are not surprising, as many investigators have highlighted similar problems relating to the variation in reproducibility of these biomarkers in EBC [3, 4]. The variations in the reproducibility of these biomarkers could be due to methodological issues regarding sampling, storage and analytical techniques of EBC. Other confounding factors for the variation would include smoking, consumption of alcohol, caffeine and a diet rich in antioxidants. The collection procedure, storage conditions and analysis of H 2 O 2 and 8-isoprostanes in EBC are controversial [2]. In this study, VAN HAYDONCK et al. [1] have attempted to clarify the discrepancy associated with reproducibility of oxidative stress biomarkers in EBC obtained from healthy nonsmokers. By using a commercially available device (EcoScreen; Erich Jaeger GmbH, Hoechberg, Germany), they collected y1 …
منابع مشابه
Inhaled steroids and mortality in COPD: bias from unaccounted immortal time
1. Rahman I. Reproducibility of oxidative stress biomarkers in breath condensate: are they reliable? Eur Respir J 2004; 23: 183–184. 2. Rosias PPR, Dompeling E, Hendriks HJE, Heijnens JWCM, Donckerwolcke RAMG, Jöbsis Q. Exhaled breath condensate in children: pearls and pitfalls. Pediatr Allergy Immunol 2004; 15: 4–19. 3. Van Hoydonck PGA, Wuyts WA, Vanaudenaerde BM, Schouten EG, Dupont LJ, Temm...
متن کاملExhaled breath condensate biomarkers in COPD.
Biomarkers in chronic obstructive pulmonary disease may be useful in aiding diagnosis, defining specific phenotypes of disease, monitoring exacerbations and evaluating the effects of drugs. Exhaled breath condensate is a noninvasive means of sampling the airways, allowing biomarkers of airway inflammation and oxidative stress to be measured. In the present review, the use of exhaled breath cond...
متن کاملEIA and GC/MS analysis of 8-isoprostane in EBC of children with problematic asthma.
Asthmatic airways are characterised by enhanced oxidative stress, which can be studied by measuring biomarkers, such as 8-isoprostane. The aims of the present study were: 1) to measure the concentrations of 8-isoprostane in exhaled breath condensate (EBC) and urine of children with problematic and well-controlled asthma; 2) to compare the concentrations of 8-isoprostane measured by gas chromato...
متن کاملNon-invasive biomarkers and pulmonary function in smokers
Limited information exists regarding measurement, reproducibility and interrelationships of non-invasive biomarkers in smokers. We compared exhaled breath condensate (EBC) leukotriene B4 (LTB4) and 8-isoprostane, exhaled nitric oxide, induced sputum, spirometry, plethysmography, impulse oscillometry and methacholine reactivity in 18 smokers and 10 non-smokers. We assessed the relationships betw...
متن کاملLC-ESI-MS/MS method for oxidative stress multimarker screening in the exhaled breath condensate of asbestosis/silicosis patients.
The sensitive assay method was developed for a parallel, rapid and precise determination of the most prominent oxidative stress biomarkers: 8-iso-prostaglandin F(2α) a lipid oxidation biomarker, o-tyrosine an amino acid oxidation biomarker and 8-hydroxy-2'-deoxy-guanosine a nucleic acid oxidation biomarker. The method consisted of a pre-treatment part, freeze drying (lyophilization), serving th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 23 2 شماره
صفحات -
تاریخ انتشار 2004