Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation

نویسندگان

  • Sean Robison
  • Gauri Rani Karur
  • Rachel M. Wald
  • Paaladinesh Thavendiranathan
  • Andrew M. Crean
  • Kate Hanneman
چکیده

BACKGROUND Calculation of cardiovascular magnetic resonance (CMR) extracellular volume (ECV) requires input of hematocrit, which may not be readily available. The purpose of this study was to evaluate the diagnostic accuracy of ECV calculated using various noninvasive measures of hematocrit compared to ECV calculated with input of laboratory hematocrit as the reference standard. METHODS One hundred twenty three subjects (47.7 ± 14.1 years; 42% male) were prospectively recruited for CMR T1 mapping between August 2016 and April 2017. Laboratory hematocrit was assessed by venipuncture. Noninvasive hematocrit was assessed with a point-of-care (POC) device (Pronto-7® Pulse CO-Oximeter®, Masimo Personal Health, Irvine, California, USA) and by synthetic derivation based on the relationship with blood pool T1 values. Left ventricular ECV was calculated with input of laboratory hematocrit (Lab-ECV), POC hematocrit (POC-ECV), and synthetic hematocrit (synthetic-ECV), respectively. Statistical analysis included Wilcoxon signed-rank test, Bland-Altman analysis, receiver-operating curve analysis and intra-class correlation (ICC). RESULTS There was no significant difference between Lab-ECV and POC-ECV (27.1 ± 4.7% vs. 27.3 ± 4.8%, p = 0.106), with minimal bias and modest precision (bias - 0.18%, 95%CI [- 2.85, 2.49]). There was no significant difference between Lab-ECV and synthetic-ECV (26.7 ± 4.4% vs. 26.5 ± 4.3%, p = 0.084) in subjects imaged at 1.5 T, although bias was slightly higher and limits of agreement were wider (bias 0.23%, 95%CI [- 2.82, 3.27]). For discrimination of abnormal Lab-ECV ≥30%, POC-ECV had good diagnostic performance (sensitivity 85%, specificity 96%, accuracy 94%, and AUC 0.902) and synthetic-ECV had moderate diagnostic performance (sensitivity 71%, specificity 98%, accuracy 93%, and AUC 0.849). POC-ECV had excellent test-retest (ICC 0.994, 95%CI[0.987, 0.997]) and inter-observer agreement (ICC 0.974, 95%CI[0.929, 0.991]). CONCLUSIONS Myocardial ECV can be accurately and reproducibly calculated with input of hematocrit measured using a noninvasive POC device, potentially overcoming an important barrier to implementation of ECV. Further evaluation of synthetic ECV is required prior to clinical implementation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive Imaging in Adult Congenital Heart Disease.

Multimodality cardiovascular imaging plays a central role in caring for patients with congenital heart disease (CHD). CHD clinicians and scientists are interested not only in cardiac morphology but also in the maladaptive ventricular responses and extracellular changes predisposing to adverse outcomes in this population. Expertise in the applications, strengths, and pitfalls of these cardiovasc...

متن کامل

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

Imaging Equilibrium Contrast Cardiovascular Magnetic Resonance for the Measurement of Diffuse Myocardial Fibrosis Preliminary Validation in Humans

Background—Diffuse myocardial fibrosis is a final end point in most cardiac diseases. It is missed by the cardiovascular magnetic resonance (CMR) late gadolinium enhancement technique. Currently, quantifying diffuse myocardial fibrosis requires invasive biopsy, with inherent risk and sampling error. We have developed a robust and noninvasive technique, equilibrium contrast CMR (EQ–CMR) to quant...

متن کامل

Imaging Association Between Extracellular Matrix Expansion Quantified by Cardiovascular Magnetic Resonance and Short-Term Mortality

Background—Extracellular matrix expansion may be a fundamental feature of adverse myocardial remodeling, it appears to be treatable, and its measurement may improve risk stratification. Yet, the relationship between mortality and extracellular matrix is not clear because of difficulties with its measurement. To assess its relationship with outcomes, we used novel, validated cardiovascular magne...

متن کامل

Association between extracellular matrix expansion quantified by cardiovascular magnetic resonance and short-term mortality.

BACKGROUND Extracellular matrix expansion may be a fundamental feature of adverse myocardial remodeling, it appears to be treatable, and its measurement may improve risk stratification. Yet, the relationship between mortality and extracellular matrix is not clear because of difficulties with its measurement. To assess its relationship with outcomes, we used novel, validated cardiovascular magne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2018