Relationships between spinal landmarks and skin surface markers.
نویسندگان
چکیده
This investigation determined relationships between coronal vertical alignment (CVA) and sagittal vertical alignment (SVA) variables calculated from radiographs and surface markers representing bony landmarks. Biplanar radiographs were taken on 28 subjects (standing) after 2 metallic surface markers were placed on the skin superficial to C7 and S2. The CVA-R and SVA-R were measured on the radiographs. Similar variables were calculated from the surface markers (CVA-P-R, SVA-P-R). Correlation between CVA-R and CVA-P-R was 0.894 (p<0.000), and between SVA-R and SVA-P-R was 0.946 (p<0.000). Results lead to three recommendations: (1) obtain surface marker data when radiographs are taken to establish relationships between the two sets of data, (2) take care in providing instructions to the subjects if measures are to be taken at different times, and (3) observe caution in interpreting results when simultaneous x-ray and surface marker data were not recorded.
منابع مشابه
مقایسه تفاوت لندمارک های آناتومیک دو تکنیک رادیوگرافی لترال سفالومتری دیجیتال و معمولی به روش ترسیم دستی در جمجمه های انسانی
Background and purpose: Digital radiography has led to many improvements in radiology. Despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. The aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques usi...
متن کاملTechnical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks.
PURPOSE Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the entire patient external surface in real time. The main objective of this study ...
متن کاملReliability and Accuracy of Palpable Anterior Neck Landmarks for the Identification of Cervical Spinal Levels
Study Design A descriptive experimental study. Purpose The purpose of this study was to describe the reliability and accuracy of palpable anterior neck landmarks (angle of the mandible, hyoid bone, thyroid cartilage, and cricoid cartilage) for the identification of cervical spinal levels in a slight neck-extended position as in anterior approach cervical spinal surgery. Overview of Literatu...
متن کاملApplication of Soft Tissue Artifact Compensation Using Displacement Dependency between Anatomical Landmarks and Skin Markers
Soft tissue artifact is known to be one of the main sources of errors in motion analysis by means of stereophotogrammetry. Among many approaches to reduce such errors, one is to estimate the position of anatomical landmarks during a motion with joint angle or displacement of skin markers, which is the so-called compensation method of anatomical landmarks. The position of anatomical landmarks wa...
متن کاملFactors predictive of topographical accuracy in spine level localization.
BACKGROUND Pre-operative spine level localization by palpation of anatomical landmarks (ribs, spinous processes) in posterior approaches for surgeries from T4 to L2 is often inaccurate. This can lead to ineffective utilization of procedural time, increased radiation dose, potentially longer skin incision and wrong level surgery. Factors affecting topographical accuracy includes body mass index ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied biomechanics
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2008