ISO 9241-9 evaluation of video game controllers

نویسندگان

  • Daniel Natapov
  • Steven J. Castellucci
  • I. Scott MacKenzie
چکیده

Fifteen participants completed a study comparing video game controllers for point-select tasks. We used a Fitts’ law task, as per ISO 9241-9, using the Nintendo Wii Remote for infrared pointing, the Nintendo Classic Controller for analogue stick pointing, and a standard mouse as a baseline condition. The mouse had the highest throughput at 3.78 bps. Both game controllers performed poorly by comparison. The Wii Remote throughput was 31.5% lower, at 2.59 bps, and the Classic Controller 60.8% lower at 1.48 bps. Comparing just the video game controllers, the Wii Remote presents a 75% increase in throughput over the Classic Controller. Error rates for the mouse, Classic Controller, and the Wii Remote were 3.53%, 6.58%, and 10.2%, respectively. Fourteen of 15 participants expressed a preference for the Wii Remote over the Classic Controller for pointing tasks in a home entertainment environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of the user-centred design process according ISO 9241-210 in air traffic control.

Designing a usable human machine interface for air traffic control is challenging and should follow approved methods. The ISO 9241-210 standard promises high usability of products by integrating future users and following an iterative process. This contribution describes the proceeding and first results of the analysis and application of ISO 9241-210 to develop a planning tool for air traffic c...

متن کامل

Evaluating Eye Tracking with ISO 9241 - Part 9

The ISO 9241-9 standard for computer pointing devices proposes an evaluation of performance and comfort [4]. This paper is the first eye tracking evaluation conforming to ISO 9241-9. We evaluated three techniques and compared them with a standard mouse. The evaluation used throughput (in bits/s) as a measurement of user performance in a multi-directional point-select task. The "Eye Tracking Lon...

متن کامل

Evaluation mobiler Computer in der klinischen Routine

Usability Studien über unterstützende technische Komponenten im Gesundheitswesen sind bislang die Ausnahme. Insbesondere mobilen Werkzeugen wurde bisher wenig Beachtung geschenkt, was auf den geringen Routineeinsatz dieser Geräte zurück zu führen ist. In der vorliegenden Arbeit werden erstmals Ergebnisse aus einer multizentrischen, externen Evaluation zur Benutzerfreundlichkeit von Handheld Ger...

متن کامل

Evaluation of Radiology and Pathology Subsystems of Hospital Information Systems

Background & Aims: Compliance with standards of designing information systems leads to efficient utilization and ease of use for consumers. In this study, the compliance of the radiology and pathology subsystems of a hospital information system with ISO 9241 section 12 was assessed in selected hospitals affiliated with Kerman University of Medical Sciences, Iran. Methods...

متن کامل

Software evaluation using the 9241 evaluator

There is an increasing need for practical and comprehensive evaluation methods and tools for conformance testing with ISO standards. In this study, we focus on ISO 9241 which is an important ergonomic standard. A brief description shows its content and structure. Practical evaluations include the amount of time and resources which must be managed in software projects, while comprehensive evalua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009