Measurements of Ground Motion and Magnet Vibrations at the Aps

نویسنده

  • Vladimir SHILTSEV
چکیده

This article presents results of ground motion and magnet vibrations measurements at the Advanced Photon Source. The experiments were done over a wide frequency range (0.05-100 Hz) with the use of SM-3KV-type seismic probes from the Budker Institute of Nuclear Physics (Russia). Spectral power densities of vertical and horizontal motions of the APS hall floor and quadrupoles on regular supports were obtained. Also investigated were magnet vibrations induced by designed cooling water flow and spectral characteristics of spatial correlation of the quadrupole vibrations at different sectors of the ring. The influence of personnel activity in the hall and traffic under the ring on the slow motion of storage ring elements were observed. Amplitudes of vibrations at the APS are compared with results of seismic measurements at some other accelerators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the Surface Quality using Combined Ultrasonic Vibration and Magnetic Abrasive Finishing Method

In this paper, a new non-contact ultrasonic abrasive finishing mechanism is designed and fabricated. This mechanism combines the function of ultrasonic vibrations and the magnetic abrasive finishing (MAF) process. A permanent magnet which is mounted on a horn has been used as the processing tool. This polishing tool is vibrated at an ultrasonic frequency with piezo-electric actuators. Ultrasoni...

متن کامل

Study of vibrations and stabilization at the sub-nanometer scale for CLIC final doublets

CLIC is one of the current projects of high energy linear colliders. Vertical beam sizes of 1nm at the collision point and fast ground motion of a few nanometres impose an active stabilization of the final doublets at a tenth of a nanometre above 5Hz. The majority of our work concerned vibrations and active stabilization studies of cantilever and slim beams in order to be representative of the ...

متن کامل

Influence of Ground Motion Duration on the Structural Response at Multiple Seismic Intensity Levels

This paper aims to investigate the effects of motion duration on the structural seismic demands, seeking potential correlations between motion durations and structural responses at several seismic intensity levels. Three seismic intensity levels with 100years, 475years, and 2475years earthquake return periods (RPs) are first considered for correlation computations. Spectrally matched ground mot...

متن کامل

In-situ Vibration Measurements of the Ctf2 Quadrupoles

The Compact LInear Collider (CLIC), presently under study at the European Organization for Nuclear Research (CERN), aims at colliding high-energy “nanobeams” at a luminosity of 10 cm−2s−1. Vibrations of the lattice elements, if not properly corrected, can result in a loss in performance by creating both unacceptable emittance growth in the linear accelerator and relative beam-beam offsets at th...

متن کامل

New Synchrotron Injection Septum Magnet at the Aps*

A new direct-drive, out-of-vacuum synchrotron injection septum magnet has been built at the Advanced Photon Source to replace the existing eddy-currentshielded, in-vacuum magnet. We describe the design, assembly, construction, and measurements.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011