Microbiologic activity in laser resurfacing plume and debris.

نویسندگان

  • P J Capizzi
  • R P Clay
  • M J Battey
چکیده

BACKGROUND AND OBJECTIVE With the increasing use of laser resurfacing, concerns have arisen about the biological hazards associated with the procedure. This study analyzed the potential bacterial and viral exposure to operating room personnel as a result of the laser smoke plume in CO2 laser resurfacing. STUDY DESIGN/MATERIALS AND METHODS Thirteen consecutive patients underwent CO2 laser resurfacing. A HEPA filter in the smoke evacuator was used to collect specimens of the laser plume smoke for cultures. The study was controlled by a second filter exposed to room air. RESULTS The 13 patients each had one bacterial, one viral, and one control culture (total, 39 specimens). In the control group, none of the 13 specimens had any growth. No viral growth has been found to date. Of 13 bacterial cultures, 5 resulted in growth of coagulase-negative Staphylococcus. Of these five positive specimens, one also had growth of Corynebacterium and one had growth of Neisseria. CONCLUSION The potential exists for operating personnel to be exposed to viable bacteria during laser resurfacing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

/Erbium Laser Safety

background. There are a variety of potential hazards with laser technology. methods. A review of the literature. objective. To summarize the potential hazards of CO 2 and erbium laser technologies and the safety guidelines and equipment developed to minimize them. results. Laser hazards can be divided into the following categories: mechanical, environmental, macrobiologic, microbiologic, and ia...

متن کامل

Erbium:YAG Laser resurfacing of periorbital skin: Report of 7 cases

Nowadays, Erbium: YAG laser resurfacing of periorbital skin has become a very popular method of wrinkle reduction. Seven patients with Fitzpatrick skin phototypes of II to V were treated with a 2940 nm Erbium: YAG laser system for resurfacing of periorbital wrinkles. Photographic evalution performed before and after treatment. Patients were visited at 1,2,3,5,7,14,30 and 60 days after laser res...

متن کامل

Antibiotic prophylaxis for full-face laser resurfacing: is it necessary?

OBJECTIVE To evaluate the need for antibiotic prophylaxis when performing full-face laser resurfacing. METHOD Prospective study of 31 patients undergoing full-face laser resurfacing, 17 with and 14 without antibiotic prophylaxis. OBSERVATION Four of 14 patients without antibiotic prophylaxis had microbiologic and clinical evidence of infection. None of the 17 patients with antibiotic prophy...

متن کامل

Wavelength dependence of prepulse laser beams on EUV emission from CO2 reheated Sn plasma

Extreme ultraviolet (EUV) emission from laser-produced plasmas (LPP) centered at 13.5 nm is considered a leading candidate for the light source in future lithography systems. Tin is currently the best material for generating this EUV emission since it emits strongly within the 13.5 nm region due to its various ionic states (SnSn). Highly efficient and low-debris LPPs are a pre-requisite for the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 1998