PIV measurements of flow in a centrifugal blood pump: steady flow.

نویسندگان

  • Steven W Day
  • James C McDaniel
چکیده

Magnetically suspended left ventricular assist devices have only one moving part, the impeller. The impeller has absolutely no contact with any of the fixed parts, thus greatly reducing the regions of stagnant or high shear stress that surround a mechanical or fluid bearing. Measurements of the mean flow patterns as well as viscous and turbulent stresses were made in a shaft-driven prototype of a magnetically suspended centrifugal blood pump at several constant flow rates (3-9 L/min) using particle image velocimetry (PIV). The chosen range of flow rates is representative of the range over which the pump may operate while implanted. Measurements on a three-dimensional measurement grid within several regions of the pump, including the inlet, blade passage, exit volute, and diffuser are reported. The measurements are used to identify regions of potential blood damage due to high shear stress and/or stagnation of the blood, both of which have been associated with blood damage within artificial heart valves and diaphragm-type pumps. Levels of turbulence intensity and Reynolds stresses that are comparable to those in artificial heart valves are reported. At the design flow rate (6 L/min), the flow is generally well behaved (no recirculation or stagnant flow) and stress levels are below levels that would be expected to contribute to hemolysis or thrombosis. The flow at both high (9 L/min) and low (3 L/min) flow rates introduces anomalies into the flow, such as recirculation, stagnation, and high stress regions. Levels of viscous and Reynolds shear stresses everywhere within the pump are below reported threshold values for damage to red cells over the entire range of flow rates investigated; however, at both high and low flow rate conditions, the flow field may promote activation of the clotting cascade due to regions of elevated shear stress adjacent to separated or stagnant flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study of the tongue geometry effects on the cavitation and performance of a centrifugal pump in off-design conditions

In this study, the effects of the volute tongue geometry variation on the head, efficiency, velocity distribution and cavitation structure of a centrifugal pump in the steady flow behavior under off-design conditions have been investigated. Numerical simulation modeling based on the  turbulence model with a hybrid grid is used to simulate the flow within the modeled pump. The flow is simulated ...

متن کامل

Experimental Study and Three-Dimensional Numerical Flow Simulation in a Centrifugal Pump when Handling Viscous Fluids

In this paper the centrifugal pump performances are tested when handling water and viscous oils as Newtonian fluids. Also, this paper shows a numerical simulation of the three-dimensional fluid flow inside a centrifugal pump. For these numerical simulations the SIMPLEC algorithm is used for solving governing equations of incompressible viscous/turbulent flows through the pump. The k-ε turbulenc...

متن کامل

PIV measurements of flow in a centrifugal blood pump: time-varying flow.

Measurements of the time-varying flow in a centrifugal blood pump operating as a left ventricular assist device (LVAD) are presented. This includes changes in both the pump flow rate as a function of the left ventricle contraction and the interaction of the rotating impeller and fixed exit volute. When operating with a pulsing ventricle, the flow rate through the LVAD varies from 0-11 L/min dur...

متن کامل

Impeller and volute design and optimization of the centrifugal pump with low specific speed in order to extract performance curves

Now a day centrifugal pumps are vital components of industries. Certainly, one of the most important specifications of centrifugal pumps are the performance curves. In the present work, performance curves of a centrifugal pumps are obtained by Computational fluid dynamics (CFD) and as an outcome, CFD results compare by practical curves. At the first step impeller and volute are designed with tw...

متن کامل

An Experimental Investigation into the Effects of High Viscosity and Foamy Oil Rheology on a Centrifugal Pump Performance

This paper presents the effect of high viscosity oil and two-phase foamy-oil flow on the performance of a single stage centrifugal pump. As a part of this, the applicability of a pipe viscometer to determine the foamy oil viscosity is investigated. Unlike previous studies, a sealed fluid tank is used in a closed flow loop to allow conditioning the two-phase mixture to create foamy-oil. Furtherm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 127 2  شماره 

صفحات  -

تاریخ انتشار 2005