Letter to the Editor: Validity of the bolton index using cone-beam computed tomography (CBCT); methodological mistake

نویسندگان

  • Siamak Sabour
  • Elahe Vahid-Dastjerdi
چکیده

We were interested to read the paper by Tarazona B, and colleagues published in the May 2012 issue of Med Oral Patol Oral Cir Bucal. The authors aimed to evaluate the reliability and reproducibility of calculating the Bolton Index using cone-beam computed tomography (CBCT), and to compare this with measurements obtained using the 2D Digital Method. They report by determining the regression lines for both measurement methods, as well as the difference between both of their values, the two methods are shown to be comparable, despite the fact that the measurements analysed presented statistically significant differences. (1) Why did the authors not use well known statistical tests as Sensitivity, Specificity, positive predictive value (PPV), negative predictive value (NPV) to test the validity of the Bolton Index? (2,3) or use other methods such as likelihood ratio positive and negative (LR+ & LR-)? (2,3) It is good to know that reliability (precision) and validity (accuracy) are two completely different methodological issues evaluating by different tests (2-4). As the authors point out in their conclusion; the threedimensional models obtained from the CBCT are as accurate and reproducible as the digital models obtained from the plaster study casts for calculating the Bolton Index. Such conclusion is just misinterpretation of the results and should really be avoided in clinical researches, otherwise; we will face with misdiagnosis and mismanagement of the patients. Sabour S, Vahid-Dastjerdi E. Validity of the bolton index using conebeam computed tomography (CBCT); Methodological mistake. Med Oral Patol Oral Cir Bucal. 2013 Sep 1;18 (5):e822-3. http://www.medicinaoral.com/medoralfree01/v18i5/medoralv18i5p822.pdf

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the validity of the Bolton Index using cone-beam computed tomography (CBCT)

AIMS To evaluate the reliability and reproducibility of calculating the Bolton Index using cone-beam computed tomography (CBCT), and to compare this with measurements obtained using the 2D Digital Method. MATERIAL AND METHODS Traditional study models were obtained from 50 patients, which were then digitized in order to be able to measure them using the Digital Method. Likewise, CBCTs of those...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Incidental dentomaxillofacial findings on cone beam computed tomography images of Iranian population

BACKGROUND AND AIM: The present study aimed to assess the nature and prevalence of incidental findings in cone beam computed tomography (CBCT) images of oral and maxillofacial patients. METHODS: In this cross-sectional study, 773 CBCT samples were retrieved from archives of a private oral and maxillofacial radiology center. Any findings that were not related to the reason of CBCT request was re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2013