Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting.

نویسندگان

  • G J Bootsma
  • F Verhaegen
  • D A Jaffray
چکیده

PURPOSE X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). METHODS The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, SMC. SMC is fit to a function, SF, and if the fit of SF is within a specified goodness of fit (GOF), the simulations are terminated. The fit, SF, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. RESULTS Pearson's correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, SF. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35-93 s and 114-122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%-50% and reduced the reconstruction error to under 3% for the simulated phantoms. CONCLUSIONS The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Scatter Artifacts Correction for Cone-Beam CT without System Modification and Repeat Scan

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed specifically for Poisson signal is then applied to derive the final scatter distribution. Qualitatively and quantitatively evaluations using Monte Carlo (MC) ...

متن کامل

Implementation of an efficient Monte Carlo calculation for CBCT scatter correction: phantom study

Cone-beam computed tomography (CBCT) images suffer from poor image quality, in a large part due to contamination from scattered X-rays. In this work, a Monte Carlo (MC)-based iterative scatter correction algorithm was implemented on measured phantom data acquired from a clinical on-board CBCT scanner. An efficient EGSnrc user code (egs_cbct) was used to transport photons through an uncorrected ...

متن کامل

A new approach to scatter correction in SPECT images based on Klein_Nishina equation

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

Determination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation

Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...

متن کامل

Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations.

Kilovoltage (kV) cone beam computed tomography (CBCT) images suffer from a substantial scatter contribution. In this study, Monte Carlo (MC) simulations are used to evaluate the scattered radiation present in projection images. These predicted scatter distributions are also used as a scatter correction technique. Images were acquired using a kV CBCT bench top system. The EGSnrc MC code was used...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 2015