Volatile generation in bell peppers during frozen storage and thawing using selected ion flow tube mass spectrometry (SIFT-MS).

نویسندگان

  • Brendan Wampler
  • Sheryl A Barringer
چکیده

UNLABELLED To determine volatile formation during storage and thawing, whole, pureed, blanched, and raw green and red bell peppers (Capsicum annuum) were frozen quickly or slowly then stored at -18 °C for up to 7 mo, with and without SnCl(2) addition during thawing. Headspace analysis was performed by a Selected Ion Flow Tube Mass Spectrometer (SIFT-MS). After blanching, (Z)-3-hexenal had a large significant decrease in concentration since it is a heat labile compound while most other volatiles did not change in concentration. The freezing process increased volatile levels in the puree only. Slow freeze peppers had higher levels of some LOX generated volatiles during storage than quick freeze. During frozen storage of blanched samples (E)-2-hexenal, (Z and E)-hexen-1-ol, and (E)-2-pentenal increased likely because of nonenzymatic autoxidation of fatty acids while other volatiles remained constant. In Raw Whole peppers, (Z)-3-hexenal, hexanal, and 2-pentylfuran were generated during storage likely because the LOX enzyme is still active during frozen storage. However, blanched samples had higher concentrations of (E)-2-hexenal, (Z and E)-hexen-1-ol, 1-penten-3-one, and (E)-2-heptenal because of enzymatic destruction of these volatiles in the raw samples. The levels of many of the volatiles in the raw samples, including (Z)-3-hexenal, (E)-2-hexenal, (Z and E)-hexen-1-ol, hexanal, (E)-2-pentenal, and 2-pentylfuran, appeared to peak around 34 d after freezing. Pureed samples had significantly higher levels of volatiles than the whole samples, and volatiles peaked earlier. Green bell pepper volatile levels were always higher than red bell pepper. Significantly higher volatile formation occurred during thawing than it did during frozen storage. PRACTICAL APPLICATION Studying and monitoring the headspace volatiles with a SIFT-MS can give information that will help manufacturers better understand how the volatiles in bell peppers change during frozen storage. This will give valuable information to processors on how to minimize volatile changes during storage of frozen peppers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

From molecules in space to molecules in breath.

The evolution of the selected ion flow tube, SIFT, used to study ion-molecule reactions of interstellar significance, to the selected ion flow tube mass spectrometry, SIFT-MS, analytical technique is described briefly. Focus is placed on the application of SIFT-MS to breath analysis and its potential for the detection of volatile biomarkers of disease including respiratory pathogens. Typical co...

متن کامل

Validation of selective ion flow tube mass spectrometry for fast quantification of volatile bases produced on Atlantic cod (Gadus morhua).

Selective ion flow tube mass spectrometry (SIFT-MS) is a direct mass spectrometric technique that allows qualitative and quantitative analysis of a large number of volatile organic compounds. Because of its speed and ease of use, this nondestructive technique could be considered as a practical tool for quality control. This research focuses on the possibilities of direct headspace sampling by S...

متن کامل

Selected ion flow-drift tube mass spectrometry, SIFDT-MS: quantification of volatile compounds in air and breath

A selected ion flow drift tube mass spectrometric analytical technique, SIFDT-MS, is described that extends the established selected ion flow tube mass spectrometry, SIFT-MS, by the inclusion of a static but variable E-field along the axis of the flow tube reactor in which the analytical ion-molecule chemistry occurs. The ion axial speed is increased in proportion to the reduced field strength ...

متن کامل

Direct detection and quantification of malondialdehyde vapour in humid air using selected ion flow tube mass spectrometry supported by gas chromatography/mass spectrometry.

RATIONALE It has been proposed that malondialdehyde (MDA) reflects free oxygen-radical lipid peroxidation and can be useful as a biomarker to track this process. For the analysis of MDA molecules in humid air by selected ion flow tube mass spectrometry (SIFT-MS), the rate coefficients and the ion product distributions for the reactions of the SIFT-MS reagent ions with volatile MDA in the presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of food science

دوره 77 6  شماره 

صفحات  -

تاریخ انتشار 2012