Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads.

نویسندگان

  • Yoshihiro Seo
  • Tomoko Ishizu
  • Hideki Nakajima
  • Yukio Sekiguchi
  • Shigeyuki Watanabe
  • Kazutaka Aonuma
چکیده

BACKGROUND This study evaluated the usefulness of 3-dimensional echocardiography (3-DE) for identifying permanent pacemaker (PPM) or implantable cardioverter defibrillator (ICD) lead-related symptomatic tricuspid regurgitation (TR). METHODS AND RESULTS Eighty-seven patients underwent 3-DE examination: 50 patients with PPM, 17 with ICD, and 20 with cardiac resynchronization therapy devices. TR severity was classified as trivial/mild, moderate, or severe according to the ratio of TR area to right atrium area. The 3-DE identified the lead route and position at the tricuspid valve in 82 patients (94.2%). In 5 patients, images without lead-induced artifacts could not be obtained. TR severity was trivial/mild in 50 patients, moderate in 20 patients, and severe in 12 patients. In all patients with trivial/mild TR and all but 1 patient with moderate TR, leads were positioned on the annulus side between leaflets. Lead-induced obstruction to tricuspid valve closing was identified in 1 patient with moderate TR and in 7 of 12 patients with severe TR: 4 patients had septal leaflet obstruction, and 4 had posterior leaflet obstruction. CONCLUSIONS The 3-DE can identify the lead route and position at the tricuspid valve and lead-related severe TR, so may be a useful technique of diagnosing the cause of severe TR in patients with PPM or ICD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads.

OBJECTIVES We report a series of patients with severe tricuspid valve regurgitation due to a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead. BACKGROUND Severe tricuspid regurgitation caused by a PPM or ICD lead is an under-recognized but treatable etiology of severe right heart failure. METHODS We reviewed the records of 41 patients who underwent tricuspid va...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography.

The most common etiology of tricuspid stenosis is rheumatic, and in most cases it is associated with valvular regurgitation. Interestingly, there have been reports of tricuspid stenosis without associated valvular regurgitation, mostly related to pacemaker leads. Percutaneous tricuspid valvuloplasty may be a therapeutic alternative to surgery in cases of pure tricuspid stenosis without other co...

متن کامل

Rupture of chorda tendineae of the tricuspid valve in a horse: a case report

A2-year-old cachectic cross-breed gelding was admitted toVeterinary Teaching Hospital of University of Tehran followingthe onset of a marked respiratory distress, coughing and ventraledema. Clinical examinations indicated harsh respiratory andexpiratory sounds as well as jugular vein distention. Therespiratory and heart rates were 35/min and 60 bpm, respectively.Agrade III/IV pansystolic murmur...

متن کامل

Evaluation of tricuspid regurgitation by pulsed Doppler and two-dimensional echocardiography.

We analyzed tricuspid regurgitation noninvasively using ultrasonic pulsed Doppler and two-dimensional echocardiography in 66 patients in whom tricuspid regurgitation was suspected from routine clinical evaluation. All of the patients also underwent right ventriculography. Ten healthy subjects served as controls. In 62 of 66 patients, the study was adequately performed. In 58 of 62 patients, pan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 72 9  شماره 

صفحات  -

تاریخ انتشار 2008