Biodegradable Polymer-Based Sirolimus-Eluting Stents With Differing Elution and Absorption Kinetics: The PANDA III Trial.

نویسندگان

  • Bo Xu
  • Runlin Gao
  • Yuejin Yang
  • Xuebin Cao
  • Lei Qin
  • Yi Li
  • Zhanquan Li
  • Xueqi Li
  • Hailong Lin
  • Yong Guo
  • Yitong Ma
  • Jian'an Wang
  • Shaoping Nie
  • Liang Xu
  • Eric Cao
  • Changdong Guan
  • Gregg W Stone
چکیده

BACKGROUND Whether the rate of drug elution and polymer absorption affects clinical outcomes of biodegradable polymer-based drug-eluting stents (DES) is unknown. The widely used polylactide polymer-based Excel stent (JW Medical, Weihai, China) elutes sirolimus within 180 days, and the polylactide polymer is completely absorbed within 6 to 9 months. In contrast, the poly-lactide-co-glycolide polymer-based BuMA stent (Sino Medical, Tianjin, China) elutes sirolimus within 30 days, and the poly-lactide-co-glycolide polymer is completely absorbed within 3 months. Thus, both metallic DES elute sirolimus, isolating major differences to the polymer and elution kinetics. OBJECTIVES The goal of this study was to compare the safety and effectiveness between the BuMA sirolimus-eluting stent (SES) and Excel SES in an "all-comers" population. METHODS PANDA III was a multicenter trial with few exclusion criteria, powered for sequential noninferiority and superiority testing. The primary endpoint was 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS Between December 2013 and August 2014, 2,348 patients were randomly assigned to treatment with BuMA (n = 1,174) or Excel SES (n = 1,174). The 1-year primary endpoint of TLF occurred in 6.4% of patients in each group (difference: 0.06%; 95% confidence interval: 1.93% to 2.04%; pnoninferiority = 0.0003; psuperiority = 0.95). There were no significant between-group differences in any of the secondary endpoints other than the incidence of definite/probable stent thrombosis, which occurred less frequently with the BuMA stent (0.5% vs. 1.3%; log-rank p = 0.048). CONCLUSIONS The BuMA SES was demonstrated to be noninferior to the Excel SES for 1-year TLF, with a lower incidence of stent thrombosis. (Comparison of BuMA eG Based BioDegradable Polymer Stent With EXCEL Biodegradable Polymer Sirolimus-eluting Stent in "Real-World" Practice [PANDA-III]; NCT02017275).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...

متن کامل

Rationale and design for the PAINT randomized trial.

BACKGROUND We describe the rationale and design for the 'PercutAneous INTervention with biodegradable-polymer based paclitaxel-eluting or sirolimus-eluting versus bare stents for de novo coronary lesions - PAINT trial'. OBJECTIVES To evaluate two novel formulations of paclitaxel-eluting stent and the sirolimus-eluting stent against a stent with the same metallic structure but without polymer ...

متن کامل

Drug-eluting stents: insights into safety and indications.

Ann Saudi Med 28(2) March-April 2008 www.kfshrc.edu.sa/annals 114 Drug-eluting stents have attracted considerable attention since their commercial approval more than 5 years ago when they were considered by some as one of the most important breakthroughs in the history of cardiovascular medicine. Different drug-eluting stents, with different drugs, different polymers, and different elution kine...

متن کامل

Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: rationale and design of the BIOSCIENCE trial.

BACKGROUND Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) w...

متن کامل

Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.

AIMS Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 67 19  شماره 

صفحات  -

تاریخ انتشار 2016