Early clinical outcomes of wavefront-guided myopic LASIK treatments using a new-generation hartmann-shack aberrometer.
نویسندگان
چکیده
PURPOSE To provide an initial retrospective evaluation of early postoperative outcomes after wavefront-guided myopic LASIK using a new-generation Hartmann-Shack wavefront sensor. METHODS A noncomparative, retrospective study of 243 eyes of 126 patients that underwent primary wavefront-guided LASIK, using wavefront data obtained with a new Hartmann-Shack aberrometer (iDesign Advanced WaveScan aberrometer; Abbott Medical Optics, Inc., Santa Ana, CA). Visual acuity, refraction, and patient satisfaction were evaluated 1 month after surgery. RESULTS The manifest spherical equivalent was reduced from -3.28 ± 1.79 diopters (D) (range: -9.88 to -0.38 D) before surgery to -0.03 ± 0.29 D (range: -1.00 to +1.25 D) 1 month after surgery. The manifest spherical equivalent was within 0.50 and 1.00 D of target in 93.0% and 99.6% of eyes, respectively. Manifest astigmatism preoperatively (-0.72 ± 0.67 [range: 0.0 to -5.00 D]) was reduced to -0.14 ± 0.20 (range: 0.0 to -1.00 D) at 1 month and the vector-derived correction ratio (surgically induced refractive change/intended refractive correction) was 1.02 ± 0.30. Uncorrected distance visual acuity of 20/16, 20/20, and 20/25 or better was achieved in 79.0%, 93.4%, and 96.7% of eyes, respectively. No eyes lost two or more lines of corrected distance visual acuity, whereas a gain of one or more lines was observed in 14.0%. Most patients (98.5%) reported that they were satisfied with the outcome of their procedure. CONCLUSIONS Wavefront-guided LASIK using the new aberrometer in this retrospective evaluation was effective, safe, and predictable in the early postoperative time period for the correction of myopia with high patient satisfaction.
منابع مشابه
Wavefront-Guided Photorefractive Keratectomy with the Use of a New Hartmann-Shack Aberrometer in Patients with Myopia and Compound Myopic Astigmatism
Purpose. To assess refractive and visual outcomes and patient satisfaction of wavefront-guided photorefractive keratectomy (PRK) in eyes with myopia and compound myopic astigmatism, with the ablation profile derived from a new Hartmann-Shack aberrometer. Methods. In this retrospective study, 662 eyes that underwent wavefront-guided PRK with a treatment profile derived from a new generation Hart...
متن کاملOutcomes of wavefront-guided laser in situ keratomileusis using a new-generation Hartmann-Shack aberrometer in patients with high myopia.
PURPOSE To evaluate refractive and visual outcomes of wavefront-guided laser in situ keratomileusis (LASIK) to correct high myopia using a new Hartmann-Shack aberrometer. SETTING Optical Express, Glasgow, United Kingdom. DESIGN Retrospective noncomparative case series. METHODS Data of eyes that had wavefront-guided LASIK for high myopia and myopic astigmatism (spherical equivalent [SE] be...
متن کاملWavefront-guided refractive surgery results of training-surgeons.
PURPOSE To assess clinical outcomes and changes on higher-order aberrations (HOA) after wavefront-guided laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) for correction of myopia and myopic astigmatism performed by training-surgeons. METHODS One hundred and seventy patients had customized LASIK (207 eyes) and PRK (103 eyes) performed by surgeons in-training using the...
متن کاملWavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial.
PURPOSE To compare visual outcomes using the WaveLight ALLEGRETTO WAVE to administer either wavefront-optimized (standard LASIK) or wavefront-guided (custom LASIK) treatments in myopic eyes. METHODS In this prospective, open-label, multicenter study conducted in the United States, 374 eyes were randomized by alternating enrollment to receive either wavefront-optimized or wavefront-guided LASI...
متن کاملVariability of wavefront aberration measurements in small pupil sizes using a clinical Shack-Hartmann aberrometer
BACKGROUND Recently, instruments for the measurement of wavefront aberration in the living human eye have been widely available for clinical applications. Despite the extensive background experience on wavefront sensing for research purposes, the information derived from such instrumentation in a clinical setting should not be considered a priori precise. We report on the variability of such an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 30 1 شماره
صفحات -
تاریخ انتشار 2014