Relationship between the angle of vertebral screws and spinal lateral angulation after fixation of thoracolumbar fractures via an anterior approach.

نویسندگان

  • L T Ma
  • Q Gong
  • T Li
  • Y M Song
  • F X Pei
  • X D Zhao
  • W L Zhang
  • L M Liu
  • J C Zeng
  • H Liu
چکیده

This study investigated possible contributors to lateral spinal angulation after surgical fixation of thoracolumbar fractures via an anterior approach. We retrospectively examined lateral angulation in 172 cases of thoracolumbar fractures treated in this manner. The coronal Cobb angle and angles of the screws relative to the endplates were determined from radiographs. The patients completed the Short Form 36, Oswestry Disability Index, Japanese Orthopaedic Association Back Pain Evaluation Questionnaire, and Visual Analogue Scale at the final follow-up visit. The mean coronal Cobb angle was 0.75° ± 3.91° (-14.25° to 14.55°) preoperatively, 3.17° ± 4.07° (-8.18° to 14.01°) immediately postoperatively, and 3.46° ± 4.21° (-1.05° to 17.27°) at the final follow-up visit. The superior posterior and inferior anterior screws were more parallel to their respective endplates when the approach was made ≥2 vs ≤1 vertebral levels above the fracture (P < 0.001). Lateral angulation was more likely when the approach was made ≤1 vs ≥2 levels above the fracture (P < 0.001). The coronal Cobb angle differed significantly (P < 0.01) between patients with lumbar and thoracic fractures. The immediate postoperative coronal Cobb angle correlated tightly with the sum of the screw angles (superior plus inferior posterior and/or inferior plus superior anterior). Lateral angulation may occur after surgical fixation of thoracic and lumbar fractures via an anterior approach. Non-parallelism between the vertebral screws and their corresponding endplates may predict postoperative lateral spinal angulation. Postoperative lateral angulation does not correlate with low back pain, quality of life, or preoperative lateral angulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior spinal fixation with pedicle screws and rods system in thoracolumbar spinal fractures.

OBJECTIVE To determine the effectiveness of posterior spinal fixation in maintaining the stability of spine and to determine mortality in 6 months after posterior spinal fixation. STUDY DESIGN Quasi experimental study. PLACE AND DURATION OF STUDY Department of Orthopaedics, Jinnah Postgraduate Medical Centre, Karachi and Department of Orthopaedics, Postgraduate Medical Institute, Hayatabad ...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Posterior internal fixation plus vertebral bone implantation under navigational aid for thoracolumbar fracture treatment

The aim of this study was to investigate the method of posterior thoracolumbar vertebral pedicle screw reduction and fixation combined with vertebral bone implantation via the affected vertebral body under navigational aid for the treatment of thoracolumbar fractures. The efficacy of the procedure was also measured. Between June 2005 and March 2011, posterior thoracolumbar vertebral pedicle scr...

متن کامل

Comparing the efficacy of short-segment pedicle screw instrumentation with and without intermediate screws for treating unstable thoracolumbar fractures

It is generally acknowledged that short-segment pedicle screw instrumentation is the preferred surgical method for thoracolumbar fractures. However, the use of short-segment instrumentation with or without intermediate screws at the fracture level remains controversial.We retrospectively evaluated 44 patients (28 men, 16 women) with unstable thoracolumbar fractures. The patients were divided in...

متن کامل

The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Genetics and molecular research : GMR

دوره 13 4  شماره 

صفحات  -

تاریخ انتشار 2014