Transverse-acceptance Measurement System for Jaea Avf Cyclotron
نویسندگان
چکیده
We are developing an acceptance measurement system to evaluate the matching of the emittance of an injection beam to the acceptance of the AVF cyclotron. The system is composed of a phase-space collimator in the low energy section and beam intensity monitors which are installed just after the phase space collimator and in the high energy section. The phase-space collimator, which consists of two pairs of movable slits, is used to inject beams with very small-emittance into the cyclotron by defining position and divergence angle of the beam from an ion source. The acceptance is measured as the phase space distribution of the ratio of the beam intensity at the high energy section to that at the phase space collimator. In the preliminary test, only a part of distribution for the acceptance was measured because the injection-beam emittance from an ion source did not cover the whole acceptance. A steering magnet has been added to expand measurable area by scanning the injection beam in synchronization with the acceptance measurement. The result of a test experiment showed the emittance of the injection beam was able to be enlarged more than ten times. It was confirmed that this technique was valid as the method of increasing the injection emittance for measuring the whole of the acceptance.
منابع مشابه
Use of Microbeam at Jaea Takasaki
The TIARA facilities of JAEA in Takasaki is equipped with a several-MeV light-ion and a several-dozen-MeV heavy-ion microbeam formation systems of focusing type, and a several-hundred-MeV heavy-ion microbeam formation system of collimating type. The microbeams with a spot size of 1 μm or less in diameter are extensively utilized for the research in materials science and biotechnology. An in-air...
متن کاملPresent Status of the Rcnp Cyclotron Facility
The Research Center for Nuclear Physics (RCNP) cyclotron cascade system has been operated to provide high quality beams for various experiments. In order to increase the physics research opportunities, the Azimuthally Varying Field (AVF) cyclotron facility was upgraded recently. A flat-topping system and an 18-GHz superconducting Electron Cyclotron Resonance (ECR) ion source were introduced to ...
متن کاملRcnp Cyclotron Facility
The Research Center for Nuclear Physics (RCNP) cyclotron cascade system has been operated to provide high quality beams for various experiments. In order to increase the physics opportunities, the Azimuthally Varying Field (AVF) cyclotron facility was upgraded recently. A flat-topping system and an 18 GHz superconducting Electron Cyclotron Resonance (ECR) ion source were introduced to improve t...
متن کاملDevelopment of the Flat-top Acceleration System for the Rcnp Avf Cyclotron
A new flat-top acceleration system has been developed for an RCNP K140 AVF cyclotron to reduce the energy spread of a beam and to improve beam transmission to an RCNP K400 ring cyclotron. A flat-top cavity with a length of 700 mm and an outer diameter of 170 mm is capacitively coupled to a main resonator. A maximum peak harmonic voltage of 5 kV can be produced on a dee electrode by feeding powe...
متن کاملMeasurement of tortuosity in aluminum foams using airborne ultrasound.
The slow compressional wave in air-saturated aluminum foams was studied by means of ultrasonic transverse transmission method over a frequency range from 0.2 MHz to 0.8 MHz. The samples investigated have three different cell sizes or pores per inch (5, 10 and 20 ppi) and each size has three aluminum volume fractions (5%, 8% and 12% AVF). Phase velocities show minor dispersion at low frequencies...
متن کامل