SPECT low-field MRI system for small-animal imaging.

نویسندگان

  • Christian Goetz
  • Elodie Breton
  • Philippe Choquet
  • Vincent Israel-Jost
  • André Constantinesco
چکیده

UNLABELLED Localization of regions with increased uptake of radiotracer in small-animal SPECT is greatly facilitated when using coregistration with anatomic images of the same animal. As MRI has several advantages compared with CT (soft-tissue contrast and lack of ionizing radiation) we developed a SPECT/low-field MRI hybrid device for small-animal imaging. METHODS A small-animal single-pinhole gamma-camera (pinhole, 1.5 mm in diameter and 12 cm in focal length) adjacent to a dedicated low-field (0.1 T) small MR imager (imaging volume, 10 x 10 x 6 cm(3)) was used. The animal was placed in a warmed nonmagnetic polymethyl methacrylate imaging cell for MR acquisition, which was followed immediately by SPECT after translation of the imaging cell from one modality to the other. 3-Dimensional T1-weighted sequences were used for MRI. Phantom studies enabled verification of a low attenuation (10%) for (99m)Tc and (201)Tl and a very slight increase in Compton scattering due to the radiofrequency coil and polymethyl methacrylate imaging cell. RESULTS SPECT/MRI data acquisition and image coregistration of selected examples using different radiotracers for lungs, kidneys, and brain were obtained in 3 nude mice with isotropic spatial resolutions of 0.5 x 0.5 x 0.5 mm(3) for MRI and 1 x 1 x 1 mm(3) for SPECT. The total acquisition time for combined SPECT and MRI lasted 1 h 45 min. CONCLUSION A low-magnetic-field strength of 0.1 T is a simple and useful solution for a small-animal dual-imaging device combining pinhole SPECT with the adjacent MR imager.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated 7T MRI and SPECT Systems for Small-Animal Imaging

Purpose MRI and single-photon emission computed tomography (SPECT) provide complimentary information which could aid in the diagnosis of various diseases. However, acquiring images from both modalities can been problematic. Until recently, SPECT systems could not be integrated with MRI systems due to the use of photomultiplier tubes which do not function in high magnetic fields. The development...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

The effect of earth magnetic field on the function of nuclear medicine imaging systems (SPECT)

Background: The nuclear medicine systems are very sensitive to the variation of the magnetic field. Photomultiplier tubes amplify low energy light signal and change it into electrical current. Low magnetic field can produce some variations in uniformity and special resolution of SPECT systems. In this study, we tried to evaluate the effects of magnetic field on the function of nuclear medic...

متن کامل

Precise Co-registration of SPECT and MRI for Small Animal Imaging using a Common Animal Bed with External References:Visualization of Macrophage Distribution within Inflammatory Lymph Nodes

Introduction: Nuclear medicine (NM) can provide unique information about sentinel lymph nodes, although it shows poor anatomical information; therefore, the superimposition of NM images on MR images would enhance the excellent features of MRI in spatial resolution and tissue contrast. A high magnetic field, however, makes it difficult to develop a combined scanner, especially in combination wit...

متن کامل

Precise co-registration of SPECT and MRI for small animal imaging using a common animal bed with external references: A feasibility study

Introduction: Nuclear medicine (NM) can provide unique information about the distribution of receptors or sentinel lymph nodes (SLNs), although it shows poor anatomical information; therefore, the superimposition of NM images on MR images would enhance the excellent features of MRI in spatial resolution and tissue contrast. A high magnetic field, however, makes it difficult to develop a combine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2008