Staphylococcus aureus bacteremia associated with intra-aortic balloon pumps.
نویسندگان
چکیده
To the Editor: Since its first clinical use in the late 1960s, intra-aortic balloon pump counterpulsation has been a significant means of supporting an inadequate myocardium.' The use of an intra-aortic balloon pump has increased greatly preceding open heart surgery for cardiogenic shock and left ventricular failure. Additional indications include other conditions such as unstable angina refractory to medical treatment and mechanical complications of acute myocardial infarction. Of all of the complications of intra-aortic balloon pumps reported over the years, septic complications are rare.' Most septic complications of intra-aortic balloon pumps are local (eg, wound infection). Methicillin-sensitive Staphylococcus aureus (MSSA) bacteremia has been reported only rarely in patients with newly inserted balloon pumps. Recently, within a period of 8 days, three patients in our cardiac care unit developed MSSA bacteremia within a week of placement of an intra-aortic balloon pump. In these three symptomatic patients, blood cultures were positive for MSSA. The following three cases describe our findings.
منابع مشابه
Fatal endocarditis with methicilin-sensible Staphylococcus aureus and major complications: rhabdomyolysis, pericarditis, and intracerebral hematoma
BACKGROUND Over the last decades Staphylococcus aureus (SA) has become the dominant etiology of native valve infective endocarditis, with the community-acquired methicillin-sensible Staphylococcus aureus (CA-MSSA) strains being the prevailing type. CASE We report here a case of extremely severe CA-MSSA aortic valve acute endocarditis associated with persistent Staphylococcus aureus bacteremia...
متن کاملStaphylococcus aureus aortitis and retroperitoneal fibrosis: A case report and literature review
An infected aortic aneurysm is a process with high mortality rate. Survival is dependent on an early diagnosis and surgical management. This case report details a rare presentation of aortitis with persistent methicillin-sensitive Staphylococcus aureus (MSSA) bacteremia, which initially presented as retroperitoneal fibrosis and was ultimately fatal.
متن کاملThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملMethicillin Resistant Staphylococcus Aureus (MRSA) Eradication Prior to Cardiac Surgery
The problem of methicillin-resistant Staphylococcus aureus (MRSA) infections has led to routine surveillance and decolonisation strategies. Cardiac surgery unit admissions receive MRSA cultures from nares, skin, throat and wounds/groin, and if positive are isolated followed by eradication treatment. This strategy was retrospectively reviewed. The study comprises 50 patients: 32 successfully dec...
متن کاملMycotic aneurysm of the femoral artery complicating Staphylococcus aureus bacteremia: a case report
INTRODUCTION Staphylococcus aureus is the major cause of bacteremia, with the potential for some complications, namely mycotic aneurysms, defined as irreversible dilatation of an artery due to destruction of the vessel wall by infection. CASE PRESENTATION The authors present the case of a 52 year-old-Caucasian male, admitted with Staphylococcus aureus bacteremia and mycotic aneurysm of the ri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Infection control and hospital epidemiology
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2003