Characteristics of glucose metabolism indexes and continuous glucose monitoring system (CGMS) in patients with insulinoma

نویسندگان

  • Weijun Gu
  • Yixin Liu
  • Hongyan Liu
  • Guoqing Yang
  • Qinghua Guo
  • Jin Du
  • Nan Jin
  • Li Zang
  • Zhaohui Lv
  • Jianming Ba
  • Yiming Mu
  • Jingtao Dou
چکیده

AIMS Analyze the clinical applicability of glucose metabolism indexes and continuous glucose monitoring data on the qualitative diagnosis of insulinoma. METHODS Involve 22 patients with insulinoma (insulinoma group), 11 patients with hypoglycemia (hypoglycemia group) and 31 people with normal glucose tolerance (control group). HbA1c, fasting blood glucose (FBG), insulin (FINS) and C-peptide (FCP) was tested. Using CGMS to monitor the blood glucose for three consecutive days and selecting the monitoring data of 24 h thereof, figuring out, with the aid of EasyGV Version 9.0, the mean glucose (MG), the standard deviation (SD) of blood glucose, CONGA (continuous overall net glycemic action), J-Index, LI (Lability Index), LBGI (Low Blood Glucose Index), HBGI (High Blood Glucose Index), GRADE (glycaemic risk assessment diabetes equation), MAGE (mean aplitude of glycaemic excursions), M value, MAG (mean absolute glucose). RESULTS (1) FBG and LBG of insulinoma group are lower than those of control group and those of hypoglycemia group while FINS and FCP of insulinoma group are markedly higher than those of the other two groups; (2) the MG and CONGA of insulinoma group are lower than those of control group and its indexes like ST, LI, LBGI, GRADE, MAGE, M value and MAG are higher than those of control group; there are differences between the indexes of insulinoma group and those of hypoglycemia group in CONGA (lower than that of hypoglycemia group), LBGI (higher than that of hypoglycemia group), and M value (higher than that of hypoglycemia group). By drawing the ROC curve and calculating Youden index, the cut-off values of LBGI, M value, CONGA are respectively as 4.06, 7.79, 4.38, and the best index of differential diagnosis is LBGI. CONCLUSION Continuous glucose monitoring data can be used to diagnose insulinoma and blood glucose fluctuation indicators such as LBGI, M value, CONGA might be useful to identify insulinoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock.

BACKGROUND Intermittent glycemic measurements in patients admitted to the intensive care unit (ICU) can result in episodes of severe hypoglycemia or in a poor control of glycemia range. We designed a study to assess accuracy and reliability of continuous monitoring of tissue glucose for patients with distributive shock. METHODS Consecutive patients admitted to the ICU with a diagnosis of dist...

متن کامل

Therapeutic Use and Diagnostic Potential of Continuous Glucose Monitoring Systems (CGMS) in Adolescents

Glucose meters provide quantitative information about blood glucose concentration that is discontinuous. Continuous glucose monitoring systems (CGMS) using sensors provide time sequences data, including “quantity,” and adding direction, rate of change and rate of acceleration. Therefore CGMS appear more informative, efficacious and safe as meters when used for treatment choices. Recently some i...

متن کامل

Clinical Performance of Continuous Glucose Monitoring System in Type 1 Diabetics

The aim of the study was to determine whether a 3-day glucose profile is sufficiently representative of the overall metabolic control of a patient, and to evaluate clinical performance of the continuous glucose monitoring system (CGMS) in type 1 diabetic patients. Eighteen type 1 diabetics (male 7, female 11, mean age 26.7±4.6 years) were included in the study performed at Outpatient Clinic of ...

متن کامل

Glucose metabolism disorder in obese children assessed by continuous glucose monitoring system.

BACKGROUND Continuous glucose monitoring system (CGMS) can measure glucose levels at 5-minute intervals over a few days, and may be used to detect hypoglycemia, guide insulin therapy, and control glucose levels. This study was undertaken to assess the glucose metabolism disorder by CGMS in obese children. METHODS Eighty-four obese children were studied. Interstitial fluid (ISF) glucose levels...

متن کامل

Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes.

CONTEXT Advantages/disadvantages of continuous vs. discrete glucose monitoring are not well documented. OBJECTIVE Compare glucose profiles from home meters vs. continuous sensors. DESIGN Randomized clinical trial conducted by the Diabetes Research in Children Network (DirecNet) to assess the utility of the GlucoWatch G2 Biographer. SETTING Home glucose measurements. PATIENTS Two hundred...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017