A randomised crossover trial comparing the Airtraq(®) NT, McGrath(®) MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin.
نویسندگان
چکیده
OBJECTIVE Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult airway scenarios. METHODS Sixty-three anaesthetists were recruited into a randomised trial in which each performed nasotracheal intubation with all laryngoscopes, in both scenarios. The main endpoint was intubation time. Additional endpoints included laryngoscopic view, intubation success, number of optimisation manoeuvres, audible dental clicks and the force applied to the upper airway. RESULTS Intubation time was significantly shorter using the McGrath MAC in both scenarios and using the Airtraq in the difficult scenario, when compared with the Macintosh laryngoscope. Both devices gave more Cormack and Lehane grade 1 or 2 views than the Macintosh in the difficult scenario (p<0.001). The McGrath MAC had the best first-attempt success rate (98.4% vs. 96.8% and 95.8%, p<0.001 for the Airtraq NT and Macintosh laryngoscopes respectively). The number of optimisation manoeuvres, audible dental clicks and subjective assessment of the degree of force applied were significantly lower for indirect laryngoscopes versus the Macintosh laryngoscope (p<0.001). CONCLUSION In a manikin, the Airtraq and the McGrath laryngoscopes appeared superior to the Macintosh laryngoscope when dealing with simulated airway scenarios. Both devices were associated with better views, intubation times and rates of success, especially in a simulated "difficult airway". Overall satisfaction was highest with the McGrath laryngoscope. Similar clinical studies are needed.
منابع مشابه
A comparison of the Airtraq®, McGrath®, and Macintosh laryngoscopes for difficult paediatric intubation: A manikin study
BACKGROUND The efficacy of devices for difficult intubation in paediatric patients, especially with a Cormack-Lehane grade 4 view, has yet to be established. We compared intubating parameters among three devices (the Airtraq®, McGrath®, and Macintosh laryngoscopes). METHODS This study is a randomised cross-over trial. Participants were 20 anaesthetists. Each device was tested three times usin...
متن کاملComparing McGRATH® MAC, C-MAC®, and Macintosh Laryngoscopes Operated by Medical Students: A Randomized, Crossover, Manikin Study
We hypothesized that the McGRATH MAC would decrease the time of intubation compared to C-MAC for novices. Thirty-nine medical students who had used the Macintosh blade to intubate a manikin fewer than 3 times were recruited. The participants performed sequential intubations on the manikin in two simulated settings that included a normal airway and a difficult airway (tongue edema). The intubati...
متن کاملThe usefulness of the McGrath MAC laryngoscope in comparison with Airwayscope and Macintosh laryngoscope during routine nasotracheal intubation: a randomaized controlled trial
BACKGROUND McGrath MAC video laryngoscope offers excellent laryngosopic views and increases the success rate of orotracheal intubation in some cases. The aim of this study was to determine the usefulness of McGrath MAC for routine nasotracheal intubation by comparing McGrath MAC with Airway scope and Macintosh laryngoscope. METHODS A total of 60 adult patients with ASA physical status class 1...
متن کاملComparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins
BACKGROUND Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq and Truview laryngoscopes may...
متن کاملEvaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy--a manikin study.
The Airtraq Laryngoscope is a novel intubation device which allows visualisation of the vocal cords without alignment of the oral, pharyngeal and tracheal axes. We compared the Airtraq with the Macintosh laryngoscope in simulated easy and difficult laryngoscopy. Twenty-five anaesthetists were allowed up to three attempts to intubate the trachea in each of three laryngoscopy scenarios using a La...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of anesthesiology
دوره 66 3 شماره
صفحات -
تاریخ انتشار 2016