Segmented nitinol guidewires with stiffness-matched connectors for cardiovascular magnetic resonance catheterization: preserved mechanical performance and freedom from heating
نویسندگان
چکیده
BACKGROUND Conventional guidewires are not suitable for use during cardiovascular magnetic resonance (CMR) catheterization. They employ metallic shafts for mechanical performance, but which are conductors subject to radiofrequency (RF) induced heating. To date, non-metallic CMR guidewire designs have provided inadequate mechanical support, trackability, and torquability. We propose a metallic guidewire for CMR that is by design intrinsically safe and that retains mechanical performance of commercial guidewires. METHODS The NHLBI passive guidewire is a 0.035" CMR-safe, segmented-core nitinol device constructed using short nitinol rod segments. The electrical length of each segment is less than one-quarter wavelength at 1.5 Tesla, which eliminates standing wave formation, and which therefore eliminates RF heating along the shaft. Each of the electrically insulated segments is connected with nitinol tubes for stiffness matching to assure uniform flexion. Iron oxide markers on the distal shaft impart conspicuity. Mechanical integrity was tested according to International Organization for Standardization (ISO) standards. CMR RF heating safety was tested in vitro in a phantom according to American Society for Testing and Materials (ASTM) F-2182 standard, and in vivo in seven swine. Results were compared with a high-performance commercial nitinol guidewire. RESULTS The NHLBI passive guidewire exhibited similar mechanical behavior to the commercial comparator. RF heating was reduced from 13 °C in the commercial guidewire to 1.2 °C in the NHLBI passive guidewire in vitro, using a flip angle of 75°. The maximum temperature increase was 1.1 ± 0.3 °C in vivo, using a flip angle of 45°. The guidewire was conspicuous during left heart catheterization in swine. CONCLUSIONS We describe a simple and intrinsically safe design of a metallic guidewire for CMR cardiovascular catheterization. The guidewire exhibits negligible heating at high flip angles in conformance with regulatory guidelines, yet mechanically resembles a high-performance commercial guidewire. Iron oxide markers along the length of the guidewire impart passive visibility during real-time CMR. Clinical translation is imminent.
منابع مشابه
MRI active guidewire with an embedded temperature probe and providing a distinct tip signal to enhance clinical safety
BACKGROUND The field of interventional cardiovascular MRI is hampered by the unavailability of active guidewires that are both safe and conspicuous. Heating of conductive guidewires is difficult to predict in vivo and disruptive to measure using external probes. We describe a clinical-grade 0.035" (0.89 mm) guidewire for MRI right and left heart catheterization at 1.5 T that has an internal pro...
متن کاملPositive contrast spiral imaging for visualization of commercial nitinol guidewires with reduced heating
BACKGROUND CMR-guidance has the potential to improve tissue visualization during cardiovascular catheterization procedures and to reduce ionizing radiation exposure, but a lack of commercially available CMR guidewires limits widespread adoption. Standard metallic guidewires are considered to be unsafe in CMR due to risks of RF-induced heating. Here, we propose the use of RF-efficient gradient e...
متن کاملSpiral imaging with off-resonance reconstruction for MRI-guided cardiovascular catheterizations using commercial off-the-shelf nitinol guidewires
Background MRI-guidance of cardiovascular catheterization offers improved soft-tissue contrast and reduced ionizing radiation exposure. The application of MRI-guidance to complex catheterization procedures has been limited by the unavailability of guidewires that are safe and visible under MRI. Here, we use RF-efficient spiral imaging for MR-guided cardiovascular catheterization, with real-time...
متن کاملStiffness-matched segmented metallic guidewire for interventional cardiovascular MRI
Background Conductive guidewires and intravascular catheters are at risk of RF-induced heating under MRI [1]. Heating is found predominantly at the tip of conductive wires [2], and is modulated by wire diameter, length and insulation thickness [3]. Non-conductive materials, such as polymer, impart unsatisfactory mechanical properties on guidewires in terms of flexibility, stiffness, and torquab...
متن کاملPositive contrast spiral imaging of a nitinol guidewire
Background The clinical translation of MRI-guided cardiovascular catheterization has been limited by the unavailability of devices that are both visible and safe under MRI. In particular, rigid metallic guidewires are essential for most catheterization procedures and are at risk of heating during MR imaging [1]. Here we present an MRI method that simultaneously improves the visualization of com...